Novel reflectometer for millimeter wave 3D holographic imaging
Authors:
- 1 May 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 647-651
Abstract
Small, portable, and low-cost millimeter wave imaging systems are desired in many nondestructive testing and imaging applications, as these system are capable of producing high-resolution images of interior of composite structures. Typically, systems capable of producing holographic three-dimensional images incorporate expensive and bulky wideband heterodyne coherent reflectometers or vector network analyzers. This paper presents a novel wideband, small, and low-cost reflectometer capable of producing holographic three-dimensional millimeter wave images.Keywords
This publication has 14 references indexed in Scilit:
- Optimum 2-D Nonuniform Spatial Sampling for Microwave SAR-Based NDE Imaging SystemsIEEE Transactions on Instrumentation and Measurement, 2012
- Non-uniform manual scanning for microwave nondestructive evaluation imaging2012
- A High-Dynamic Range Heterodyne Microwave Receiver for Modulated Scattering MeasurementsIEEE Transactions on Instrumentation and Measurement, 2011
- Portable Real-Time Microwave Camera at 24 GHzIEEE Transactions on Antennas and Propagation, 2011
- Quantitative Microwave Imaging for Breast Cancer Detection Using a Planar 2.45 GHz SystemIEEE Transactions on Instrumentation and Measurement, 2010
- Microwave Radar-Based Differential Breast Cancer Imaging: Imaging in Homogeneous Breast Phantoms and Low Contrast ScenariosIEEE Transactions on Antennas and Propagation, 2010
- Software-defined calibration for FMCW phased-array radar2010
- Calibration of a wideband FMCW radar used for microwave SAR imaging2002
- Three-dimensional millimeter-wave imaging for concealed weapon detectionIEEE Transactions on Microwave Theory and Techniques, 2001
- Microwave holography: Applications and techniquesProceedings of the IEEE, 1977