This study examines the power conversion performance of an oscillating water column (OWC) wave energy converter installed inside artificial wave-dissipating blocks through laboratory wave flume experiments. A square OWC model was tested under both regular and irregular wave conditions, with and without surrounding wave-dissipating blocks, and with PTO damping introduced by an orifice-type nozzle. The results show that the presence of wave-dissipating blocks significantly alters the frequency-dependent response of the internal water column. Short-period oscillations are strongly suppressed, while differences in response and efficiency between the cases with and without blocks become smaller at longer wave periods. Under irregular wave conditions, although overall efficiency is reduced, a substantial level of pneumatic power generation is maintained inside the block-protected region, particularly for long-period waves. Furthermore, the influence of PTO damping is found to differ depending on the presence of wave-dissipating blocks. For the nozzle configuration tested in this study, both regular and irregular wave experiments show that, at longer wave periods, higher chamber pressure and conversion efficiency can be achieved when wave-dissipating blocks are present, even under the same PTO damping condition. These results indicate that OWCs surrounded by wave-dissipating blocks can retain practical power conversion performance, particularly for long-period waves, and highlight the importance of jointly considering wave period characteristics and PTO damping when designing OWC systems integrated with wave-dissipating structures.