Abstract
The conventional equivalent-input-disturbance (EID) approach exhibits two estimation errors that degrade the disturbance-suppression performance. This article aims to suppress the effects of estimation errors and improve disturbance-suppression performance. Taking the errors to be an artificial disturbance, several other EID compensators are connected to suppress the disturbance. Simplifying the connected EID compensators yields the design of a parameter, $p$ , in the conventional EID estimator. Based on such an idea, this article presents a parallel-EID (PEID) approach, which has many merits. The disturbance-suppression performance of this approach is better than that of previous related studies, while its configuration is simple and universal. The physical meaning of $p$ is clear and explains the reason why the disturbance-suppression performance improves. Furthermore, this article designs a novel virtual filter for transforming the PEID-based control system into an equivalent configuration that is easy to derive stability conditions. Finally, the PEID approach is applied in controlling the speed of a permanent magnet synchronous motor. Additionally, comparisons between the conventional EID, improved EID, PEID, and modified EID approaches show the validity and superiority of the PEID approach.
Funding Information
  • National Natural Science Foundation of China (61873348)
  • Japan Society for the Promotion of Science (JSPS) Kakenhi (22H03998)

This publication has 42 references indexed in Scilit: