Corrosion behavior of HA-316L SS biocomposites in aqueous solutions
Authors:
Open Access
- 20 August 2013
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 16 (6) , 1254-1259
Abstract
316L stainless steel and Hydroxyapatite (5, 20 and 50 wt. (%) HA)-316L stainless steel composites were fabricated by mechanical alloying technique, pressing and sintering from 316L and HA powders. The corrosion behavior of both sintered 316L and HA-316L composites was evaluated by electrochemical techniques in simulated body fluid (Ringer's solution) and in 0.1M HCl solution which simulates occluded cell corrosion conditions. The results indicate that 316L stainless steel and HA-316L composites are passive in Ringer's solution and active in HCl solution. All materials are highly corrosion resistant in Ringer's solution with corrosion current density in the order of 10-6 A cm-2 or less. Both 316L stainless steel and 5% HA-316L composite present good corrosion resistance in HCl with corrosion current density in the order of 10-5 A cm-2. The corrosion resistance decreases with increasing HA content in both solutions.Keywords
This publication has 12 references indexed in Scilit:
- Corrosion Resistance of Nickel-Free Austenitic Stainless Steels and their Nanocomposites with Hydroxyapatite in Ringer's SolutionMaterials Science Forum, 2011
- Corrosion resistance of nickel‐free austenitic stainless steels/hydroxyapatite compositesphysica status solidi (c), 2010
- The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS ImplantsJournal of Materials Engineering and Performance, 2009
- Bone-like apatite formation on HA/316L stainless steel composite surface in simulated body fluidTransactions of Nonferrous Metals Society of China, 2009
- Evaluation of hydroxyapatite coatings on borate passivated 316L SS in Ringer's solutionMaterials Science and Engineering: C, 2009
- Electrophoretic deposition of natural hydroxyapatite on medical grade 316L stainless steelMaterials Science and Engineering: C, 2008
- In vitro electrochemical evaluation and phase purity of natural hydroxyapatite coating on medical grade 316L stainless steelMaterials and Corrosion, 2008
- Physico-chemical properties and microstructure of hydroxyapatite-316L stainless steel biomaterialsJournal of Central South University of Technology, 2004
- Characterization of hydroxyapatite– and bioglass–316L fibre composites prepared by spark plasma sinteringMaterials Letters, 2004
- Observation of microcracks formed in HA-316L compositesMaterials Letters, 2003