Two-Year Outcomes of Visian Implantable Collamer Lens with a Central Hole for Correcting High Myopia
Open Access
- 3 July 2018
- journal article
- research article
- Published by Wiley in Journal of Ophthalmology
- Vol. 2018, 1-9
Abstract
Purpose. To investigate two-year outcomes of Visian Implantable Collamer Lens with a central hole (ICL V4c) implantation for correcting high myopia.Methods. Sixty-one eyes of 32 patients went through ICL V4c implantation. Safety, efficacy, predictability, and intraocular pressure were evaluated 2 years postoperatively. Anterior chamber volume (ACV), anterior chamber depth (ACD), anterior chamber angle width (ACAW), and vault were measured using a Scheimpflug tomography imaging system.Results. At 2 years, the spherical equivalent refraction decreased from preoperative −14.62 ± 4.29 D to −0.90 ± 0.95 D, with 79% of the eyes within ±0.50 D and 98% within ±1.00 D of the intended correction. The efficacy index was 1.03 ± 0.23, and the safety index was 1.24 ± 0.26. Corrected distance visual acuity (CDVA) remained unchanged in 23% of the eyes, 75% gained one or more lines of CDVA, and 2% lost one line. The ACV, ACD, and ACAW, respectively, decreased from 193.28 ± 29.15 mm3, 3.15 ± 0.23 mm, and 36.51 ± 6.54 degree to 112.48 ± 17.01 mm3, 2.99 ± 0.23 mm, and 22.54 ± 5.27 degree (, resp.). Intraocular pressure was 15.39 ± 2.88 mmHg before surgery and was 15.86 ± 4.11 mmHg at 2 years ().Conclusion. Implantation of ICL V4c is a safe, effective, and predictable procedure for correcting high myopia. Reduction of anterior chamber space after surgery did not induce intraocular pressure increase during the 2-year follow-up.
Keywords
Funding Information
- Project of Shanghai Science and Technology (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- Project of Shanghai Science and Technology (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- Natural Science Foundation of China for Young Scholars (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- Natural Science Foundation of China for Young Scholars (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- Shanghai Shenkang Hospital Development Center (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- National Natural Science Foundation of China (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
- National Natural Science Foundation of China (17140902900, 17411950200, 81700872, 81500753, SHDC12016207, 81770955, 81570879)
This publication has 28 references indexed in Scilit:
- Comparative Study of 2 Types of Implantable Collamer Lenses, 1 With and 1 Without a Central Artificial HoleAmerican Journal of Ophthalmology, 2014
- Comparison of Optical Quality and Intraocular Scattering after Posterior Chamber Phakic Intraocular Lens with and without a Central Hole (Hole ICL and Conventional ICL) Implantation Using the Double-Pass InstrumentPLOS ONE, 2013
- Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correctionJournal of Cataract & Refractive Surgery, 2013
- Three-Year Follow-Up of Posterior Chamber Toric Phakic Intraocular Lens Implantation for Moderate to High Myopic AstigmatismPLOS ONE, 2013
- High Prevalence of Myopia and High Myopia in 5060 Chinese University Students in ShanghaiInvestigative Ophthalmology & Visual Science, 2012
- Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopiaBritish Journal of Ophthalmology, 2011
- Three-year follow-up of subjective vault following myopic implantable collamer lens implantationGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eyeGraefe's Archive for Clinical and Experimental Ophthalmology, 2006
- Implantable contact lens for moderate to high myopiaJournal of Cataract & Refractive Surgery, 2003