Mechanical Modeling of Tibial Axial Accelerations Following Impulsive Heel Impact
Authors:
- David M. AndrewsDADavid M. Andrews
- James J. DowlingJDJames J. Dowling
- 1 August 2000
- journal article
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 16 (3) , 276-288
Abstract
A fourth order mass/spring/damper (MSD) mechanical model with linear coefficients was used to estimate axial tibial accelerations following impulsive heel impacts. A generic heel pad with constant stiffness was modeled to improve the temporal characteristics of the model. Subjects (n= 14) dropped (~5 cm) onto a force platform (3 trials), landing on the right heel pad with leg fully extended at the knee. A uni-axial accelerometer was mounted over the skin on the anterior aspect of the medial tibial condyle inferior to the tibial plateau using a Velcro™ strap (normal preload ~45 N). Model coefficients for stiffness (k1, k2) and damping (c1, c2) were varied systematically until the minimum difference in peak tibial acceleration (%PTAmin) plus maximum rate of tibial acceleration (%RTAmax) between the estimated and measured curves was achieved for each trial. Model responses to mean subject and mean group model coefficients were also determined. Subject PTA and RTA magnitudes were reproduced well by the model (%PTAmin= 1.4 ± 1.0 %, %RTAmin= 2.2 ± 2.7%). Model estimates of PTA were fairly repeatable for a given subject despite generally high variability in the model coefficients, for subjects and for the group (coefficients of variation: CVk1= 57; CVk2= 59; CVc1= 48; CVc2= 85). Differences in estimated parameters increased progressively when subject and group mean coefficients (%PTAsub= 8.4 ± 6.3%, %RTAsub= 18.9 ± 18.6%, and %PTAgrp= 19.9 ± 15.2 %, %RTAgrp= 30.2 ± 30.2%, respectively) were utilized, suggesting that trial specific calibration of coefficients for each subject is required. Additional model refinement seems warranted in order to account for the large intra-subject variability in coefficients.Keywords
This publication has 34 references indexed in Scilit:
- Human pendulum approach to simulate and quantify locomotor impact loadingJournal of Biomechanics, 1995
- The mechanical characteristics of the human heel pad during foot strike in running: An in vivo cineradiographic studyJournal of Biomechanics, 1994
- Measurement of the Impulsive Bone Motion by Skin-Mounted AccelerometersJournal of Biomechanical Engineering, 1993
- Large Deformation Analysis of Orthodontic AppliancesJournal of Biomechanical Engineering, 1990
- In-Vivo Elastic and Damping Response of the Human Leg to Impact ForcesJournal of Biomechanical Engineering, 1982
- Effect of prolonged walking on concrete on the knees of sheepJournal of Biomechanics, 1982
- The Effect of Soft Tissue on Measurements of Vibrational Bone Motion by Skin-Mounted AccelerometersJournal of Biomechanical Engineering, 1979
- Musculo-skeletal shock absorption: Relative contribution of bone and soft tissues at various frequenciesJournal of Biomechanics, 1978
- The effect of soft tissue on wave-propagation and vibration tests for determining the in vivo properties of boneJournal of Biomechanics, 1977
- The Effect of Impact Loading on Rabbit Knee JointsActa Orthopaedica, 1977