Magneto-Mechanical Resonance in a Model 3-Phase 3-Limb Transformer Core Under Sinusoidal and PWM Voltage Excitation
Authors:
- YaoXiao Guang YaoYYYaoXiao Guang Yao
- Thant P. P. PhwayTPThant P. P. Phway
- A. J. MosesAMA. J. Moses
- Fatih AnayiFAFatih Anayi
- 16 December 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 44 (11) , 4111-4114
Abstract
This investigation presents the measurement results of acoustic noise and vibration of a model three-phase three-limb transformer core under sinusoidal and PWM voltage excitation for assigned value of modulation index with switching frequency from 1 kHz to 3 kHz at no-load condition. Results show that the acoustic noise decreased around 2 (dBA) with increasing switching frequency. However, magneto-mechanical resonance phenomenon was observed at 3 kHz vibration frequency, which could cause excess acoustic noise under some excited conditions.Keywords
This publication has 5 references indexed in Scilit:
- Magnetisation-induced mechanical resonance in electrical steelsJournal of Magnetism and Magnetic Materials, 2007
- Normal Flux Distribution in a Three-Phase Transformer Core Under Sinusoidal and PWM ExcitationIEEE Transactions on Magnetics, 2007
- Study of an AC-AC indirect converter for application as line conditioner2005
- Relevance of magnetostriction and forces for the generation of audible noise of transformer coresIEEE Transactions on Magnetics, 2000
- Effects of transformer core design on noise levelJournal de Physique IV, 1998