Abstract
Transvenous cardiac procedures require accurate positioning of catheters within the geometrically complex cavities of the heart. Recently, nonfluoroscopic catheter tracking technologies have been developed to quantitate the (degrees-of-freedom) three-dimensional positions of intracardiac catheters. This paper presents a projection-Procrustes method to register an animated three-dimensional (3-D) model of multiple intracardiac catheters with a single-plane fluoroscopic image. Applying the computed transformation to the catheter coordinates enables the animated 3-D model of the catheters to be viewed from the same perspective as the fluoroscopic image. Mathematical simulations show that the computed transformation parameters are sensitive to both the position errors in the 3-D catheter coordinates and to the spatial distribution of the catheter-mounted transducers. Simulations with a realistic geometric model of three catheters with four transducers per catheter showed an angular error of 1.91/spl deg//spl plusmn/0.27/spl deg/ for 3-D catheter position errors of 2.0 mm. An in vitro experiment demonstrated the feasibility of the method using a water tank phantom of three catheters and fluoroscopic images taken over an 80/spl deg/ range. The mean angular error was 0.61/spl deg//spl plusmn/0.48/spl deg/. The results of this study indicate that the projection-Procrustes method is a useful tool for registering 3-D catheter tracking models to single-plane fluoroscopic images.Keywords
This publication has 13 references indexed in Scilit:
- Anatomy‐Guided Linear Atrial Lesions for Radiofrequency Catheter Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 1998
- Determination of three‐dimensional positions of known sparse objects from a single projectionMedical Physics, 1997
- Application of sonomicrometry and multidimensional scaling to cardiac catheter trackingIEEE Transactions on Biomedical Engineering, 1997
- Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localizationThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Use of sonomicrometry and multidimensional scaling to determine the three-dimensional coordinates of multiple cardiac locations: feasibility and initial implementationIEEE Transactions on Biomedical Engineering, 1995
- Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections.Circulation, 1991
- Determination of three‐dimensional structure in biplane radiography without prior knowledge of the relationship between the two views: TheoryMedical Physics, 1989
- Image intensifier distortion correctionMedical Physics, 1987
- Compilation of empirical ultrasonic properties of mammalian tissues. IIThe Journal of the Acoustical Society of America, 1980
- Position-Location Solutions by Taylor-Series EstimationIEEE Transactions on Aerospace and Electronic Systems, 1976