Abstract
The synchrotron radiation emitted from the adiabatic toroidal compressor (ATC) tokamak plasma along a major radius was measured over a band of frequencies ( with resolution and rise time μsec) that included the electron cyclotron frequency and its first few harmonics. The radiation is at least 50% polarized (). Radiation due to runaway electrons increases sharply and coincidentally with the appearance of positive spikes in the loop voltage and decays exponentially after the onset of an oscillation in the plasma.
Keywords
This publication has 9 references indexed in Scilit:
- Electron Cyclotron Emission from a Tokamak Plasma: Experiment and TheoryPhysical Review Letters, 1974
- The runaway electron discharge regime in the Tokamak-6 deviceNuclear Fusion, 1973
- Runaway-electron drift surfaces and magnetic surfaces in LT-3Nuclear Fusion, 1973
- Cyclotron radiation from a rarefied inhomogeneous magnetoplasmaNuclear Fusion, 1973
- A Bandpass Filter System for Far-Infrared Radiation MeasurementsReview of Scientific Instruments, 1973
- Synchrotron radiation from a magnetically confined nonneutral hot-electron plasmaThe Physics of Fluids, 1973
- Adiabatic Compression of the Tokamak DischargePhysical Review Letters, 1972
- Synchrotron radiation in TokamaksNuclear Fusion, 1970
- Indium Antimonide Submillimeter Photoconductive DetectorsApplied Optics, 1965