Blepharo-Tensiometer
- 1 September 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 38 (5) , 326-330
Abstract
Purpose: To assess a newly developed eyelid pressure measurement system called a blepharo-tensiometer that uses a tactile pressure sensor. Methods: The tactile sensor was 10 mm in diameter and approximately 0.4 mm thick. The sensor was covered with silicon rubber and was placed between a soft contact lens on the cornea and the inner surface of the eyelid. Under these conditions, the sensor measured the pressure of the eyelid on the ocular surface. The pressure of the upper and lower eyelids were measured separately while the eyelids were closed for at least 5 seconds in 34 eyes of 34 normal volunteers. To determine the reliability of the blepharo-tensiometer, the pressures of the upper and lower eyelids were measured on 3 separate days in both eyes of 12 normal volunteers. The correlation between the age and the eyelid pressure was calculated. Results: The intraclass correlation coefficients for the 3 measurements ranged from 0.675 to 0.911 for the upper eyelid and 0.663 to 0.925 for the lower eyelid. The mean eyelid pressure was 16.95±6.08 mm Hg for the upper lid and 16.11±7.27 mm Hg for the lower lid. The eyelid pressure decreased with increasing age, and both the upper and lower eyelid pressures were significantly and negatively correlated with age (upper eyelid pressures, P<0.0001; lower eyelid pressures, P=0.000432). No complication was detected after the measurements in all of the subjects. Conclusions: Our blepahro-tensiometer can obtain repeatable measurements of the eyelid pressure and can be used to evaluate the pressure of the eyelids on the ocular surface in normal and diseased eyes.Keywords
This publication has 16 references indexed in Scilit:
- Severe cicatrical ectropion: Repair with a large advancement flap and autologous fascia slingJournal of Plastic, Reconstructive & Aesthetic Surgery, 2006
- Factors Influencing Lid Pressure on the CorneaEye & Contact Lens: Science & Clinical Practice, 2006
- Functional aspects of the tear film lipid layerExperimental Eye Research, 2004
- Filamentary keratitis improved by blepharoptosis surgery: two casesActa Ophthalmologica Scandinavica, 2003
- Blink‐related microtrauma: when the ocular surface harms itselfClinical & Experimental Ophthalmology, 2003
- Kinetic Analysis of Tear Interference Images in Aqueous Tear Deficiency Dry Eye before and after Punctal OcclusionInvestigative Ophthalmology & Visual Science, 2003
- A Longitudinal Study of Corneal Astigmatism and Total AstigmatismOptometry and Vision Science, 1981
- Etiology of AstigmatismOptometry and Vision Science, 1978
- ASTIGMATISM ITS COMPONENTS AND THEIR CHANGES WITH AGEOptometry and Vision Science, 1971
- Die Richtung der Hauptmeridiane des astigmatischen AugesGraefe's Archive for Clinical and Experimental Ophthalmology, 1869