DEVELOPMENT AND RESEARCH OF THE FUNCTIONAL POSSIBILITIES OF THE AUTOMATED FUZZY INDOOR AIR QUALITY MANAGEMENT SYSTEM OF PRODUCTION PREMISES
Open Access
- 31 December 2023
- journal article
- research article
- Published by National Scientific and Research Institute of Industrial Safety and Occupational Safety and Health in Labour protection problems in Ukraine
- Vol. 39 (3-4) , 36-42
Abstract
Purpose. Development of a fuzzy indoor air quality control system and research of the efficiency of an automated complex for increasing the concentration of air ions, namely a small-sized ultrasonic generator of air ions and a pump unit in the conditions of a complex ventilated air environment of work premises. Design/methodology/approach. The comprehensive research carried out is important in the context of the development of measures and means and the research of their effectiveness in maintaining the aeroionic regime of industrial premises at the regulatory level. Conclusions. The structure of an intelligent indoor air quality control system is proposed, which implements a combined change in the rotation speed of the fan and pump and the power of the ultrasonic aeroion generator. For the first time, a formalized criterion for the optimality of the indoor air quality management system is proposed, which depends on individual preferences of people regarding the comfort of the production environment and standardized parameters of temperature, relative humidity, and concentration of air ions in the working space. The task of the intelligent control system is to minimize the proposed criterion. Limitations/consequences of research. The proposed recommendations are universal and can be used in various areas of business to create safe and harmless working conditions in production. Practical consequences. The use of the developed small-sized ultrasonic aeroion generator not only significantly increases the concentration of aeroions in the working area, but also due to the baloelectric effect minimizes the negative impact inherent in most existing ionizers, namely the generation of ozone and nitrogen oxide, which significantly improves indoor air quality and thereby increases the level of industrial safety and labor protection. Originality/meaning. The existing control systems assume that standard ionizers (corona discharges) are inserted in the room, so there was a need to develop and research a modern intelligent system for controlling the quality of the indoor air in the working area of industrial premises using an aeroion generator and automated displacement ventilation.Keywords
This publication has 13 references indexed in Scilit:
- DEVELOPMENT OF WAYS TO MINIMIZATION OF HUMAN FACTOR SIGNS IN OCCUPATIONAL HEALTH AND SAFETYJOURNAL of Donetsk mining institute, 2020
- Minimization of the “human factor” influence in Occupational Health and SafetyNaukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, 2019
- Assessing the impact of processes on the Occupational Safety and Health Management System’s effectiveness using the fuzzy cognitive maps approachSafety Science, 2019
- OHSAS 18001 certification and work accidents: Shedding light on the connectionJournal of Safety Research, 2019
- Occupational Health and Safety Management Systems Applications and A System Planning ModelProcedia Computer Science, 2019
- Safety in the Workplace2019
- Actualization of the scientific principles elaboration on evaluating the risks of occupational danger occurrenceNaukovyi Visnyk Natsionalnoho Hirnychoho Universytetu, 2018
- Delphi assessment of occupational hazards in the wineries of Andalusia, in southern SpainJournal of Cleaner Production, 2018
- Development of the method for the optimal management of occupational risksEastern-European Journal of Enterprise Technologies, 2018
- Operational monitoring in the technological process in the aspect of occupational riskProcedia Manufacturing, 2017