Abstract
This article focuses on the little-studied pitch gearbox. Due to the intermittent operation of the pitch gearbox, there are currently no suitable methods for automatically identifying the effective vibration signal. The variable speed operation of the pitch gearbox causes the amplitude of the effective vibration signal to attenuate, rendering current instantaneous frequency estimation methods ineffective. To address these issues, the amplitude and frequency characteristics of each component in the vibration signal of the pitch gearbox are analyzed. Then, a method for identifying the effective vibration signal is proposed, which combines high-pass filtering and moving median filtering. High-pass filtering removes low-frequency components. Moving median filtering removes broadband high-amplitude components. Finally, a method for estimating the instantaneous frequency of effective vibration signals based on the short-time fractional Fourier transform is proposed. This method is accurate and not sensitive to amplitude. The experimental results show that the proposed method is superior to comparison methods in the accuracy of identification and estimation. Therefore, the proposed method lays a foundation for the monitoring and diagnosis of the pitch gearbox.
Funding Information
  • Fundamental Research Funds for the Central Universities (2023JG005, 2023JC010)
  • Major Research and Development of Jilin Science and Technology Development Program (20220203077SF)
  • Jilin Provincial Department of Education Research Project (JJKH20230129KJ)
  • Huzhou Natural Science Foundation (2023YZ14)
  • Inner Mongolia Autonomous Region Natural Science Foundation of China (2024QN06020)

This publication has 36 references indexed in Scilit: