Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study
Open Access
- 11 June 2018
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 32 (10) , 1579-1589
Abstract
Purpose To evaluate 3-year incidence of Nd:YAG capsulotomy and PCO and compare the effect of different IOL materials. Methods Data were retrospectively collected from seven UK ophthalmology clinics using Medisoft electronic medical records. Eyes from patients ≥65 years undergoing cataract surgery with implantation of acrylic monofocal IOLs during 2010–2013 and 3-year follow-up were analysed. Nd:YAG capsulotomy and PCO incidence proportions were reported for 3 IOL cohorts: AcrySof, other hydrophobic and hydrophilic acrylic IOLs. Unadjusted/adjusted odds ratios (OR) of Nd:YAG capsulotomy were calculated through logistic regression for non-AcrySof cohorts versus AcrySof. A sub-group analysis in single-piece IOLs (>90% of sample eyes) was also performed. Results The AcrySof cohort included 13,329 eyes, non-AcrySof hydrophobic 19,025 and non-AcrySof hydrophilic 19,808. The 3-year Nd:YAG capsulotomy incidence (95% CI) for AcrySof (2.4%, 2.2–2.7%) was approximately two times lower than non-AcrySof hydrophobic IOLs (4.4%, 4.1–4.7%) and approximately fourfold lower than non-AcrySof hydrophilic IOLs (10.9%, 10.5–11.3%). Trends were similar in PCO incidence (AcrySof: 4.7%; non-AcrySof hydrophobic: 6.3%; non-AcrySof hydrophilic: 14.8%). Also in the analysis restricted to single-piece IOLs, the pattern remained (2.4% vs 5.1% vs. 10.9%, respectively). Adjusted regression analysis showed a approximately two and fivefold increased odds of Nd:YAG for non-AcrySof hydrophobic and hydrophilic acrylic IOLs respectively vs. AcrySof IOLs. Nd:YAG capsulotomy ORs were similar and remained statistically significant in the single-piece IOL sub-group. Conclusions Real-world evidence shows that within 3 years following implantation, AcrySof IOLs are significantly superior in reducing Nd:YAG capsulotomy and PCO incidence compared to other hydrophilic and hydrophobic acrylic IOLs.Keywords
This publication has 28 references indexed in Scilit:
- Intraindividual comparative analysis of capsule opacification after implantation of 2 single-piece hydrophobic acrylic intraocular lenses models: Three-year follow-upJournal of Cataract & Refractive Surgery, 2015
- Posterior Capsule Opacification with the iMics1 NY-60 and AcrySof SN60WF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized TrialAmerican Journal of Ophthalmology, 2013
- Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2011
- Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2010
- Prospective evaluation of posterior capsule opacification in myopic eyes 4 years after implantation of a single-piece acrylic IOLJournal of Cataract & Refractive Surgery, 2009
- Effect of intraocular lens design on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2008
- Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002
- Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantationJournal of Cataract & Refractive Surgery, 2001
- Clinical assessment of long-term safety and efficacy of a widely implanted polyacrylic intraocular lens materialAmerican Journal of Ophthalmology, 2000
- Posterior capsule opacification 3 years after implantation of an AcrySof and a MemoryLens in fellow eyesJournal of Cataract & Refractive Surgery, 2000