Active power measurement uncertainty modelling and propagation analysis in case of harmonically distorted signals
Open Access
- 1 August 2023
- journal article
- research article
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 12 (3) , 1-10
Abstract
The harmonic distortion of electrical waveforms results in a need for instruments’ performance evaluation in non-sinusoidal conditions. Specifications, which are valid for sine-wave input signals, are not supposed to be applied directly for uncertainty determination in case of harmonics, due to the non-linear dependence between the measured quantities and the single harmonic components’ magnitudes and phase shifts. Uncertainty calculation is especially challenging in case of power and/or energy measurements, because the corresponding instruments are used for legal metrology purposes i.e. in the regulated trade of electrical energy. The starting point for the concrete evaluation is related to determination of influence factors, which affect the recording of single harmonics’ magnitudes and phase shifts. For overall power and/or energy uncertainty calculation, mathematical modelling, based on analytical relations between single harmonic components and the measured quantity, will be performed. A GUM based perspective for uniting single influence factors is implemented and a simplified approach for the correlation coefficients calculation is adopted. The validation of the model, as well as, the uncertainty propagation analysis due to single harmonic components alteration, is backed up by real time measurements, conducted with high accuracy class measurement equipment.Keywords
This publication has 12 references indexed in Scilit:
- Analysis of Errors in Active Power and Energy Measurements Under Random Harmonic Distortion ConditionsMeasurement Science Review, 2021
- Defining an Uncertainty Budget in Electrical Power and Energy Reference Standards Calibration2019
- Effect of harmonic distortion on electric energy meters of different metrological principlesFrontiers in Energy, 2018
- Analysis of the impact of nonlinear distortion in voltage and current curves on the errors of electric energy metering devices2017
- An Experimental Study of the Effect of Current THD to kWh Meter’s Energy MeasurementIJIREEICE, 2017
- Testing Of Energy Meters Under Three-Phase Determined And Random Nonsinusoidal ConditionsMetrology and Measurement Systems, 2014
- On Testing the Electronic Revenue Energy MetersIEEE Transactions on Instrumentation and Measurement, 2009
- Selecting calibration waveforms for power analyzers and meters under nonsinusoidal conditions2008
- Evaluation of Energy Meters' Accuracy Based on a Power Quality Test PlatformElectric Power Components and Systems, 2007
- Comparison of power definitions for reactive power compensation in nonsinusoidal conditions2005