Analytical and numerical sensitivity analyses of fixtures de-embedding
- 22 September 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 440-444
Abstract
De-embedding procedures are sensitive to manufacturing variations in test fixtures, as well as inaccuracies associated with the calibration and measurement process. Such sensitivities can propagate through de-embedding procedures, resulting in amplified errors. In this paper, analytical and numerical techniques are used to perform sensitivity studies on both simulation and measurement data, with respect to de-embedding.Keywords
This publication has 5 references indexed in Scilit:
- Optimization of the transition from connector to PCB board2013
- De-embedding errors due to inaccurate test fixture characterizationIEEE Electromagnetic Compatibility Magazine, 2012
- Influence of Nonideal Calibration Items on S-Parameter Uncertainties Applying the SOLR Calibration MethodIEEE Transactions on Instrumentation and Measurement, 2008
- Uncertainty of VNA S-Parameter Measurement Due to Nonideal TRL Calibration ItemsIEEE Transactions on Instrumentation and Measurement, 2005
- A three-step method for the de-embedding of high-frequency S-parameter measurementsIEEE Transactions on Electron Devices, 1991