Simultaneous determination of guaifenesin enantiomers and ambroxol HCl using 50‐mm chiral column for a negligible environmental impact
Abstract
Chiral stationary phases are conveniently used for enantiomeric separation of drugs by liquid chromatography. Consumption of large volumes of hazardous solvents is considered as a common challenge for the sustainability of this technique. To this end, a columnar chromatography has been adopted using 50‐mm‐length stationary phases. The study comprised five Phenomenex Lux cellulose‐ and amylose‐based columns for the separation of guaifenesin (GUA) enantiomers. In addition, an experimental design was used to optimize the gradient profile for the separation of racemic GUA and ambroxol HCl (AMB) binary mixture. The chromatographic method was achieved using Lux Cellulose‐1 (50 × 4.6 mm) as a chiral stationary phase and ethanol/water as a mobile phase with linear gradient elution of 20% to 70% ethanol in 6 minutes at a flow rate of 1.0 mL min−1and UV detection at 270 nm. Linearity ranges were found to be 50 to 1000 μg mL−1and 15 to 450 μg mL−1for each GUA enantiomer and AMB, respectively. Environmental, health and safety tool was used to assess and compare greenness of the proposed and reported methods. Short column indeed reduces the environmental impact by decreasing waste by about 60% and utilizing only 1‐mL ethanol in the mobile phase. The proposed method is a safer alternative for the simultaneous determination of drugs in their combined pharmaceutical formulation. The method has been validated and compared favorably with a reported one.Keywords
This publication has 28 references indexed in Scilit:
- Development and validation of a stability-indicating LC method for simultaneous determination of related compounds of guaifenesin, terbutaline sulfate and ambroxol HCl in cough syrup formulationJournal of Saudi Chemical Society, 2014
- Evaluation of the chiral recognition properties as well as the column performance of four chiral stationary phases based on cellulose (3,5-dimethylphenylcarbamate) by parallel HPLC and SFCJournal of Chromatography A, 2011
- Green chiral HPLC enantiomeric separations using high temperature liquid chromatography and subcritical water on chiralcel OD and chiralpak ADChirality, 2011
- Using dispersive liquid–liquid microextraction and liquid chromatography for determination of guaifenesin enantiomers in human urineJournal of Separation Science, 2011
- Simultaneous analysis of phenylephrine hydrochloride, guaiphenesin, ambroxol hydrochloride, and salbutamol (as salbutamol sulphate) by use of a validated high-performance liquid chromatographic methodActa Chromatographica, 2011
- Chiral separations of some β‐adrenergic agonists and antagonists on AmyCoat column by HPLCChirality, 2009
- Separation of Racemic Chiral Drugs Using Immobilized CHIRALPAK IA: Methodology for Preparative Scale DevelopmentSeparation Science and Technology, 2009
- Role of racemization in optically active drugs developmentChirality, 2007
- Enantioseparation of some clinically used drugs by HPLC using cellulose Tris (3,5‐dichlorophenylcarbamate) chiral stationary phaseBiomedical Chromatography, 2003
- Assessing Safety, Health, and Environmental Impact Early during Process DevelopmentIndustrial & Engineering Chemistry Research, 2000