Cryoballoon Pulmonary Vein Isolation with Real‐Time Recordings from the Pulmonary Veins
- 30 October 2009
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (11) , 1203-1210
Abstract
Introduction: Cryoballoon (CB) ablation represents a novel technology for pulmonary vein isolation (PVI). We investigated feasibility and safety of CB‐PVI, utilizing a novel spiral catheter (SC), thereby obtaining real‐time PV potential registration. Methods: Following double transseptal puncture, a Lasso catheter (Biosense Webster, Diamond Bar, CA, USA) and the 28 mm CB were positioned within the left atrium. A novel SC (Promap, ProRhythm Inc., Ronkonkoma, NY, USA) was inserted through the lumen of the CB allowing PV signal registration during treatment. Time to PV conduction block was analyzed. If no stable balloon position was obtained, the SC was exchanged for a regular guide wire and PV conduction was assessed after treatment by Lasso catheter. Results: In 18 patients, 39 of 72 PVs (54%) were successfully isolated using the SC. The remaining 33 PVs were isolated switching to the regular guide wire. Time to PV conduction block was significantly shorter in PVs in which sustained PVI was achieved as compared to PVs in which PV conduction recovered within 30 minutes (33 ± 21 seconds vs 99 ± 65 seconds). In 40 PVs, time to PV conduction block was not obtained because of: (1) PVI not being achieved during initial treatment; (2) a distal position of the SC; or (3) isolation with regular guide wire. No procedural complications occurred. Conclusion: Visualization of real‐time PV conduction during CB PVI is safe, feasible, and allows accurate timing of PVI onset in a subset of PVs. Time to PV conduction block predicts sustained PVI. However, mechanical properties of the SC need to be improved to further simplify CB PVI.Keywords
This publication has 19 references indexed in Scilit:
- Focal Atrial Tachycardia Originating from the Right Atrial Appendage: First Successful Cryoballoon IsolationJournal of Cardiovascular Electrophysiology, 2009
- The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre studyEuropean Heart Journal, 2008
- Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcomeEuropean Heart Journal, 2007
- Time to Electrode Rewarming After Cryoablation Predicts Lesion SizeJournal of Cardiovascular Electrophysiology, 2007
- Venice Chart International Consensus Document on Atrial Fibrillation AblationJournal of Cardiovascular Electrophysiology, 2007
- External and Endoluminal Analysis of Left Atrial Anatomy and the Pulmonary Veins in Three‐Dimensional Reconstructions of Magnetic Resonance Angiography: The Full Insight from InsideJournal of Cardiovascular Electrophysiology, 2006
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Complete Isolation of Left Atrium Surrounding the Pulmonary VeinsCirculation, 2004
- Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillationJACC, 2004
- Factors Associated with Recurrence of Accessory Pathway Conduction After Radiofrequency Catheter AblationPacing and Clinical Electrophysiology, 1991