Searching for WIMPs with TREX-DM: achievements and challenges
Authors:
Preprint
Abstract
The TREX-DM detector, a low background chamber with microbulk Micromegas readout, was commissioned in the underground laboratory of Canfranc (LSC) in 2018. Since then, data taking campaigns have been carried out with Argon and Neon mixtures, at different pressures from 1 to 4 bar. By achieving a low energy threshold of 1 keV$_{ee}$ and a background level of 80 counts keV$^{-1}$ Kg$^{-1}$ day$^{-1}$ in the region from 1 to 7 keV$_{ee}$, the experiment demonstrates its potential to search for low-mass WIMPs. Two of the most important challenges currently faced are the reduction of both, background level and energy threshold. With respect to the energy threshold, recently a new readout plane is being developed, based on the combination of Micromegas and GEM technologies, aiming to have a pre-amplification stage that would permit very low energy thresholds, close to the single-electron ionization energy. With respect to the background reduction, apart from studies to identify and minimize contamination population, a high sensitivity alpha detector is being developed in order to allow a proper material selection for the TREX-DM detector components. Both challenges, together with the optimization of the gas mixture used as target for the WIMP detection, will take TREX-DM to explore regions of WIMP's mass below 1 GeV c$^{-2}$.Keywords
All Related Versions
This publication has 9 references indexed in Scilit:
- AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contaminationJournal of Instrumentation, 2022
- Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors2021
- Status of the TREX-DM experiment at the Canfranc Underground LaboratoryJournal of Physics: Conference Series, 2020
- Background assessment for the TREX dark matter experimentThe European Physical Journal C, 2019
- Status of low mass WIMP detector TREX-DMJournal of Physics: Conference Series, 2019
- New CAST limit on the axion–photon interactionNature Physics, 2017
- TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detectionThe European Physical Journal C, 2016
- A STUDY OF MICROMEGAS WITH PREAMPLIFICATION WITH A SINGLE GEM2002
- MICROMEGAS: a high-granularity position-sensitive gaseous detector for high particle-flux environmentsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996