Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients
Authors:
- Kostoula ArvanitiKAKostoula Arvaniti
- Dimitrios LathyrisDLDimitrios Lathyris
- Phyllis Clouva-MolyvdasPCPhyllis Clouva-Molyvdas
- Anna-Bettina HaidichAHAnna-Bettina Haidich
- Eleni MouloudiEMEleni Mouloudi
- Eleni SynnefakiESEleni Synnefaki
- Vasiliki KoulouridaVKVasiliki Koulourida
- Dimitrios GeorgopoulosDGDimitrios Georgopoulos
- Nikoleta GerogianniNGNikoleta Gerogianni
- Georgios NakosGNGeorgios Nakos
- Dimitrios MatamisDMDimitrios Matamis
- 1 February 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 40 (2) , 420-429
Abstract
To evaluate silver-impregnated (Oligon) central venous catheters and chlorhexidine-gluconate-impregnated sponges for reducing catheter-related colonization and infection, nonbacteremic or bacteremic. Multicenter, prospective, randomized, controlled study. Five general intensive care units in Greece. Intensive care unit patients requiring a multilumen central venous catheter between June 2006 and May 2008. Patients were randomly assigned to receive a standard catheter (standard group), a standard catheter plus chlorhexidine-gluconate-impregnated sponge (chlorhexidine-gluconate-impregnated sponge group), or an Oligon catheter (Oligon group). Catheter colonization was defined as a positive quantitative tip culture (≥10 colony-forming units/mL), catheter-related infection was defined by the previous criterion plus clinical evidence of sepsis, and bacteremia catheter-related infection as catheter-related infection plus a positive peripheral blood culture with the same micro-organism as in the catheter tip. Data were obtained from 465 patients, 156 in the standard-group, 150 in the chlorhexidine-gluconate-impregnated sponge group, and 159 in the Oligon-group. Colonization occurred in 24 (15.4%) standard catheters, 21 (14%) in the chlorhexidine-gluconate-impregnated sponge group, and 25 (15.7%) in the Oligon catheters (p = .35) (20.9, 19.9, 21.8/1000 catheter-days, respectively). Catheter-related infections were recorded in nine (5.8%) standard catheters, six (4%) in the chlorhexidine-gluconate-impregnated sponge group, and seven (4.4%) in the Oligon catheters (p = .58) (7.8/1,000, 5.7/1,000, 6.1/1,000 catheter-days, respectively). No difference was observed between the chlorhexidine- gluconate-impregnated sponge group and the standard group regarding catheter colonization (hazard ratio 1.21; 95% confidence interval 0.56-2.61; p = .64) and catheter-related infections (hazard ratio 0.65; 95% confidence interval 0.23-1.85; p = .42). The Oligon catheter did not reduce colonization or catheter-related infections when compared with the standard catheter (colonization: hazard ratio 1.0; 95% confidence interval 0.46-2.21; p = .98; catheter-related infection: hazard ratio 0.72; 95% confidence interval 0.27-1.95; p = .52). Seven patients (1.5%, 2.09/1,000 catheter-days) presented bacteremic catheter-related infections. Central venous catheters inserted either in the internal jugular or the femoral vein had greater risk to be colonized than catheters inserted in the subclavian vein (internal jugular vs. subclavian: hazard ratio 3.29; 95% confidence interval 1.26-8.61; p = .01; femoral vs. subclavian: hazard ratio 3.36; 95% confidence interval 1.17-9.65; p = .02). Acinetobacter baumannii was the predominant pathogen (37.1% episodes of colonization, 36.4% catheter-related infections, 57.1% bacteremic catheter-related infections). For short-term (median duration 7 days) central venous catheters in intensive care units with high prevalence of multiresistant Gram-negative bacteria, chlorhexidine-impregnated sponges and Oligon catheters as single preventive measures did not reduce catheter colonization or catheter-related infections. As a result of the limited amount of events, no conclusion could be reached regarding bacteremic catheter-related infections. The femoral site was the most frequently colonized insertion site in all types of catheters.Keywords
This publication has 19 references indexed in Scilit:
- Managing bloodstream infections in patients who have short-term central venous cathetersCleveland Clinic Journal of Medicine, 2011
- Does microbial resistance or adaptation to biocides create a hazard in infection prevention and control?Journal of Hospital Infection, 2010
- Effectiveness of impregnated central venous catheters for catheter related blood stream infection: a systematic reviewCurrent Opinion in Infectious Diseases, 2008
- Antimicrobial coating of central venous catheters: Show me the data*Critical Care Medicine, 2007
- Use of chlorhexidine-impregnated dressing to prevent vascular and epidural catheter colonization and infection: a meta-analysisJournal of Antimicrobial Chemotherapy, 2006
- Réactualisation de la douzième conférence de consensus de la Société de réanimation de langue française (SRLF) : infections liées aux cathéters veineux centraux en réanimationAnnales Françaises d'Anesthésie et de Réanimation, 2005
- Cost–Benefit Analysis of Chlorhexidine Gluconate Dressing in the Prevention of Catheter-Related Bloodstream InfectionsInfection Control & Hospital Epidemiology, 2004
- Are Antimicrobial-Impregnated Catheters Effective? Don't Throw Out the Baby with the BathwaterClinical Infectious Diseases, 2004
- Infectious Complications of Indwelling Vascular CathetersClinical Infectious Diseases, 1992
- Use of a Chlorhexidine Dressing to Reduce Microbial Colonization of Epidural CathetersAnesthesiology, 1990