Immobilized ferrocene and glucose oxidase on titanium(IV) oxide grafted onto a silica gel surface and its application as an amperometric glucose biosensor
Authors:
- 1 May 1996
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 8 (5) , 489-493
Abstract
The voltammograms obtained with an electrode containing carbon paste with ferrocene immobilized on a titanium‐oxide/silica gel material showed good response and stability in aqueous media. From pH 4 to 8 the electrode response remained almost constant, but a small shift in the midpoint potential towards more positive values was observed when the pH was decreased. The nature of the cation does not affect the voltammetric response. However, the nature of the anion affects the midpoint potential significantly. Cyclic voltammetry investigation showed that the electrode with immobilized glucose oxidase is an excellent biosensor. The mechanism of the electron transfer was proposed as being electron tunneling by the flavin of the enzyme to mediator, and the high current level is assigned to the high surface area of the silica matrix. The amperometric measurements showed a linear response in the range from 1.0 × 10−4 to 8.0 × 10−4 M. Above this range, saturation of the enzyme was observed. The response time was about 15 s. Determination of glucose in blood serum showed an excellent correlation when compared with Merck's Kit method. The immobilized material presented an excellent stability mantaining the same activity for at least six months.Keywords
This publication has 30 references indexed in Scilit:
- Surface modification of carbon and platinum electrodes using TiCl4Langmuir, 1994
- Polyferrocenes as mediators in amperometric biosensors for glucoseAnalytica Chimica Acta, 1993
- Electrical Communication Between Glucose Oxidase and Novel Ferrocene-Containing Siloxane-Ethylene Oxide Copolymers: Biosensor ApplicationsAnalytical Letters, 1993
- Mediated amperometric biosensor for hypoxanthine based on a hydroxymethylferrocene-modified carbon paste electrodeAnalytica Chimica Acta, 1991
- Use of titanium species for the immobilization of cellsTransition Metal Chemistry, 1990
- Electrochemical parametrization of metal complex redox potentials, using the ruthenium(III)/ruthenium(II) couple to generate a ligand electrochemical seriesInorganic Chemistry, 1990
- Amperometric glycolate sensors based on glycolate oxidase and polymeric electron transfer mediatorsAnalytica Chimica Acta, 1990
- A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with a poly(ester-sulfonic acid) cation-exchangerAnalytica Chimica Acta, 1990
- Electrochemical responses of electrodes coated with redox polymers. Evidence for control of charge-transfer rates across polymeric layers by electron exchange between incorporated redox sitesJournal of the American Chemical Society, 1981
- Effect of internal diffusion in heterogeneous enzyme systems: Evaluation of true kinetic parameters and substrate diffusivityJournal of Theoretical Biology, 1973