Application of torsional tuned liquid column gas damper for plan-asymmetric buildings
Author:
- 9 March 2010
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 18 (5) , 492-509
Abstract
In this paper, the control performance of the novel sealed, torsional tuned liquid column gas damper (TTLCGD) to reduce the coupled flexural torsional response of plan‐asymmetric buildings under wind or seismic loads is investigated. Applications of the TTLCGD with a sealed piping system to tall building effectively increase the modal structural damping. If the modal center of velocity lies within the floor plan, TTLCGD with its in plane curved piping section encloses this center for best efficiency. Based on the linearized equation of motion for the TTLCGD‐main structure system with respect to a selected natural frequency, the optimal parameters of TTLCGD are modally tuned by means of a geometrical transformation in analogy to the classical torsional tuned mechanical damper, TTMD, followed by fine‐tuning in the state space domain considering the influence of neighboring modes to improve the performance of TTLCGD. Numerical simulations of plan‐asymmetric space frames illustrate that TTLCGD is an effective control device in suppressing the time‐harmonic excitation and the earthquake response. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 10 references indexed in Scilit:
- Performance of Multi-TMD in the Towers of Suspension BridgesJournal of Vibration and Control, 2009
- Two-stage optimum design of tuned mass dampers with consideration of strokeStructural Control and Health Monitoring, 2009
- Semi-active control of seismically excited base-isolated building model with friction pendulum systemsStructural Control and Health Monitoring, 2008
- Mitigation of seismic responses on building structures using MR dampers with Lyapunov-based controlStructural Control and Health Monitoring, 2007
- Control of pedestrian-induced vibrations of long-span bridgesStructural Control and Health Monitoring, 2005
- The moving contact line with weak viscosity effects – an application and evaluation of Shikhmurzaev’s modelActa Mechanica, 2005
- Simulating a conical tuned liquid damperSimulation Modelling Practice and Theory, 2003
- Multiple‐tuned liquid column dampers for torsional vibration control of structures: theoretical investigationEarthquake Engineering & Structural Dynamics, 2002
- Multiple‐tuned liquid column dampers for torsional vibration control of structures: experimental investigationEarthquake Engineering & Structural Dynamics, 2002
- Tuned liquid column damper for suppressing pitching motion of structuresEngineering Structures, 2000