Clinical and radiographic outcomes of reverse shoulder arthroplasty performed with 40 mm polyethylene glenospheres vs. 36 mm cobalt chrome glenospheres at minimum 2-years follow-up
- 17 September 2026
- journal article
- research article
- Published by SAGE Publications in Shoulder & Elbow
Abstract
Introduction: Most reverse total shoulder arthroplasty utilise a cobalt chrome (CoCr) glenosphere with a polyethylene liner. The Lima Shoulder Modular Replacement (SMR)™ platform has inverted the materials to potentially decrease polyethylene debris when the humeral liner contacts the scapula. Methods: This retrospective, multi-centre study was conducted to examine the equivalence of the Lima SMR™ 40 mm highly cross-linked polyethylene (XLPE) glenospheres to the 36 mm CoCr glenospheres, examining patients from 2013 to 2022 with a minimum of 2-year clinical and radiographic follow-up. Results: 199 patients were investigated: 107 with the XLPE glenosphere and 92 with the CoCr glenosphere. At 2-year follow-up, there was no significant difference in Oxford Shoulder scores ( p = 0.081). There were more areas of glenoid radiolucency in the CoCr group ( n = 18 zones in eight patients) at 2 years ( z = −2.04, p = 0.04). There was no significant difference in notching (16% in the XLPE group, 20% in CoCr group ( p = 0.190)). Two patients in the XLPE group were revised and five in the CoCr group. Discussion: XLPE glenosphere outcomes were largely equivalent to a CoCr glenosphere at 2 years. While the XLPE glenosphere had fewer major complications, this could be attributed to other factors including the larger diameter, rather than the polyethylene glenosphere. Level of evidence: Level III – retrospective comparative studyKeywords
Funding Information
- DJO Global (This project was sponsored by Enovis, however Enov)
This publication has 23 references indexed in Scilit:
- Long-term clinical and radiographic outcomes after inverted-bearing reverse total shoulder arthroplasty: a multicenter study with the Affinis Inverse prosthesisJournal of Shoulder and Elbow Surgery, 2025
- A 10-year comparative analysis of the 2 most common reverse total shoulder arthroplasty implants (Delta Xtend and SMR) in the New Zealand Joint RegistryJournal of Shoulder and Elbow Surgery, 2025
- Inverted-bearing reverse shoulder arthroplasty: long-term survivorship, complications, clinical, and radiological outcomesJournal of Shoulder and Elbow Surgery, 2024
- Effect of glenosphere size on reverse shoulder arthroplasty revision rate: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR)Journal of Shoulder and Elbow Surgery, 2022
- Minimal clinically important difference (MCID) for patient-reported shoulder outcomesJournal of Shoulder and Elbow Surgery, 2020
- Reverse Total Shoulder Arthroplasty: Biomechanics and IndicationsCurrent Reviews in Musculoskeletal Medicine, 2019
- Influence of glenosphere size on the development of scapular notching: a prospective randomized studyJournal of Shoulder and Elbow Surgery, 2016
- Osteolysis around total knee arthroplasty: A review of pathogenetic mechanismsActa Biomaterialia, 2013
- Is retrospective application of the Oxford Shoulder Score valid?Journal of Shoulder and Elbow Surgery, 2009
- Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: Range of motion and risk of scapular notchingJournal of Shoulder and Elbow Surgery, 2009