A survey of transcutaneous blood gas monitoring among European neonatal intensive care units
Open Access
- 10 August 2005
- journal article
- research article
- Published by Springer Nature in BMC Pediatrics
- Vol. 5 (1) , 30
Abstract
Background: PCO2 and PO2 are important monitoring parameters in neonatal intensive care units (NICU). Compared to conventional blood gas measurements that cause significant blood loss in preterms, transcutaneous (tc) measurements allow continuous, non-invasive monitoring of blood gas levels. The aim of the study was to survey the usage and opinions among German speaking NICUs concerning tc blood gas monitoring. Methods: A questionnaire was developed and sent to 56 head nurses of different NICUs in Germany, Switzerland and Austria. Results: A completely answered questionnaire was obtained from 41 NICUs. In two of these units tc measurements are not performed. In most NICUs (77%), both PtcO2 and PtcCO2 are measured simultaneously. Most units change the sensors every 3 hours; however, the recommended temperature of 44°C is used in only 15% of units. In only 8% of units are arterial blood gases obtained to validate tc values. Large variations were found concerning the targeted level of oxygen saturation [median upper limit: 95% (range 80–100%); median lower limit: 86% (range 75–93%)] and PO2 [median upper limit: 70 mmHg (range 45–90 mmHg); median lower limit: 44 mmHg (range 30–60 mmHg)]. Conclusion: Our survey shows that the use of tc monitors remains widespread among German speaking NICUs, despite earlier data suggesting that their use had been abandoned in many NICUs worldwide. In addition, we suggest that the current method of monitoring oxygenation may not prevent hyperoxemia in preterm infants.Keywords
This publication has 19 references indexed in Scilit:
- The clinical utility of arterialized earlobe capillary blood in the assessment of patients for long-term oxygen therapyRespiratory Medicine, 2001
- Responsibility for Clinical InnovationEvaluation & the Health Professions, 1998
- Carbon dioxide-induced retinopathy in the neonatal ratCurrent Eye Research, 1998
- Doctors and the health industry: A case study of transcutaneous oxygen monitoring in neonatal intensive careSocial Science & Medicine, 1996
- Measurement of Transcutaneous Carbon Dioxide in Low Birthweight Infants During the First Two Weeks of LifeAmerican Journal of Perinatology, 1994
- A Cohort Study of Transcutaneous Oxygen Tension and the Incidence and Severity of Retinopathy of PrematurityNew England Journal of Medicine, 1992
- Oxygen Toxicity in the Neonatal PeriodActa Paediatrica, 1990
- Comparison of capillary and arterial blood gas measurements in neonates.Archives of Disease in Childhood, 1988
- Reliability of Transcutaneous Oxygen Monitoring of Critically III Children in a General Pediatric UnitClinical Pediatrics, 1983
- TRANSCUTANEOUS Po2MONITORING IN NEONATAL INTENSIVE CAREActa Paediatrica, 1978