Measurement of temperature dependence of sound velocity in biological tissues

Authors:

Abstract
Transcatheter arterial chemo-embolization using Lipiodol ® is one of the treatments for hepatocellular carcinoma. During this procedure, it is important to monitor the Lipiodol ® deposited inside tumors. This study proposes a method for measurement of the temperature dependence of the velocity of sound in biological tissues. An ultrasonic pulse-echo method was used to measure the velocity of sound. The temperature coefficients of the velocity of sound for Lipiodol ® was −2.82 m s −1 °C −1 . Values of 1.07 and 1.59 m s −1 °C −1 were obtained for normal rat liver and cancerous liver tissue, respectively. Thus, this procedure may potentially allow for the evaluation of the infiltration of Lipiodol ® inside tumors.

This publication has 17 references indexed in Scilit: