Treatment of irregular astigmatism with a 213 nm solid-state, diode-pumped neodymium:YAG ablative laser
- 1 October 2004
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (10) , 2145-2151
Abstract
Purpose: To present the outcome of photorefractive keratectomy (PRK) using a new neodymium:YAG (Nd:YAG) laser in patients with irregular astigmatism. Setting: Claremont Eye Clinic, Claremont, and the University of Western Australia, Perth, Australia. Methods: In 3 patients with irregular astigmatism, PRK was performed with a solid-state, 213 nm wavelength, 300 Hz scanning-spot, diode-pumped Nd:YAG ablative laser (CustomVis® Pulzar® laser system). The 3 patients had had previous PRK with penetrating keratoplasty, astigmatic keratotomy, or limbal relaxing incisions. At 3 and 6 months, best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), manifest refraction, contrast sensitivity, and corneal topography were measured. Results: The first patient had a 1-line improvement in BSCVA and a 4-line improvement in UCVA, a 3.00 diopter (D) decrease in keratometric cylinder, and improvement in contrast sensitivity. The second patient had a 7.00 D decrease in myopia in 1 meridian and a 4.25 D decrease in the refractive cylinder in the other meridian. The third patient had a 2-line improvement in BSCVA, a 5-line improvement in UCVA, a 2.00 D decrease in the refractive cylinder, and improvement in contrast sensitivity. Conclusion: The laser's combination of a small spot, a fast pulse rate, and ultrafast tracking/scanning resulted in good results in 3 patients with difficult irregular astigmatism.Keywords
This publication has 13 references indexed in Scilit:
- Spot size and quality of scanning laser correction of higher-order wavefront aberrationsJournal of Cataract & Refractive Surgery, 2002
- Topography-guided excimer laser ablation of irregular cornea resulting from penetrating injuryJournal of Cataract & Refractive Surgery, 2002
- Treatment of Corneal Surface Irregularities Using BioMask as an Adjunct to Excimer Laser Phototherapeutic KeratectomyCornea, 2002
- Corneal interactive programmed topographic ablation customized photorefractive keratectomy for correction of postkeratoplasty astigmatismOphthalmology, 2001
- Topography-driven excimer laser for the retreatment of decentralized myopic photorefractive keratectomy11The authors have no proprietary interest in any of the materials used in this studyOphthalmology, 2001
- Topography-driven photorefractive keratectomy Results of corneal interactive programmed topographic ablation softwareOphthalmology, 2000
- Topographically-guided laser in situ keratomileusis to treat corneal irregularitiesOphthalmology, 2000
- Selective zonal ablations with excimer laser for correction of irregular astigmatism induced by refractive surgeryOphthalmology, 2000
- Excimer laser correction of high astigmatism after keratoplastyJournal of Cataract & Refractive Surgery, 1996
- Excimer Laser Ablation Rate and Corneal HydrationAmerican Journal of Ophthalmology, 1994