Voxel-based Morphometry of Alzheimer’s Disease Using a Localizer Image: A Comparative Study with Magnetization Prepared Rapid Acquisition with Gradient Echo
Authors:
Open Access
- 1 January 2025
- journal article
- research article
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 24 (1) , 103-111
Abstract
Purpose: Magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequence is a gold-standard technique for voxel-based morphometry (VBM) because of high spatial resolution and excellent tissue contrast, especially between gray matter (GM) and white matter (WM). Despite its benefits, MPRAGE exhibits distinct challenge for VBM in some patients with neurological disease because of long scan time and motion artifacts. Speedily acquired localizer images may alleviate this problem. This study aimed to evaluate the feasibility of VBM using 3D Fast Low Angle Shot image captured for localizer (L3DFLASH).Methods: Consecutive 13 patients with pathologically confirmed Alzheimer’s disease (AD) (82 ± 9 years) and 21 healthy controls (HC) (79 ± 4 years) were included in this study. Whole-brain L3DFLASH and MPRAGE were captured and preprocessed using the Computational Anatomy Toolbox 12 (CAT12). Agreement with MPRAGE was evaluated for L3DFLASH using regional normalized volume for segmented brain areas. In addition to brain volume difference on VBM and Bland-Altman analysis, atrophic pattern of AD on VBM was evaluated using L3DFLASH and MPRAGE.Results: Acquisition time was 18 s for L3DFLASH and 288 s for MPRAGE. There was a slight systematic difference in all regional normalized volumes from L3DFLASH and MPRAGE. For the whole cohort, GM volume measured from MPRAGE was greater than that from L3DFLASH in most of the region on VBM. When AD and HC were compared, AD-related atrophic pattern was demonstrated in both L3DFLASH and MPRAGE on VBM, although the difference was noted in significant clusters between them.Conclusion: Although systematic difference was noted in regional brain volume measured from L3DFLASH and MPRAGE, AD-related atrophic pattern was preserved in L3DFLASH on VBM. VBM, using speedily acquired localizer image, may provide limited but useful information for evaluating brain atrophy.Keywords
This publication has 46 references indexed in Scilit:
- Effect of MRI acquisition acceleration via compressed sensing and parallel imaging on brain volumetryMagnetic Resonance Materials in Physics, Biology and Medicine, 2021
- Characteristic asymmetric limbic and anterior temporal atrophy in demented patients with pathologically confirmed argyrophilic grain diseaseNeuroradiology, 2019
- Impact of multiple pathologies on the threshold for clinically overt dementiaActa Neuropathologica, 2017
- MRI morphometry in Alzheimer’s diseaseAgeing Research Reviews, 2016
- Voxel and surface-based topography of memory and executive deficits in mild cognitive impairment and Alzheimer’s diseaseBrain Imaging and Behavior, 2012
- National Institute on Aging–Alzheimer’s Association guidelines for the neuropathologic assessment of Alzheimer’s disease: a practical approachActa Neuropathologica, 2011
- A harmonized classification system for FTLD-TDP pathologyActa Neuropathologica, 2011
- Adaptive non‐local means denoising of MR images with spatially varying noise levelsJournal of Magnetic Resonance Imaging, 2009
- Customization of normal data base specific for 3-tesla MRI is mandatory in VSRAD analysisRadiological Physics and Technology, 2008
- Voxel-Based Morphometry—The MethodsNeuroImage, 2000