Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins
Authors:
- 1 March 1988
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 70-B (2) , 199-201
Abstract
One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.Keywords
This publication has 5 references indexed in Scilit:
- Internal fixation of femoral neck fractures: Compression screw compared with nail plate fixationActa Orthopaedica, 1984
- Osteosynthesis of femoral neck fracture: The sliding-screw-plate with or without compressionActa Orthopaedica, 1984
- Two-year follow-up of femoral neck fractures: Comparison of osteosynthesis methodsActa Orthopaedica, 1984
- Axial Compression in Femoral Neck Osteotomies: A Biomechanic Study in Human Cadaver HipsActa Orthopaedica, 1983
- Treatment of Displaced Fractures of the Femoral Neck:Smith-Petersen Osteosynthesis versus Sliding-Nail-Plate OsteosynthesisActa Orthopaedica, 1981