Ability of short-time low peep challenge to predict fluid responsiveness in mechanically ventilated patients in the intensive care
Authors:
- 2 September 2021
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 36 (4) , 1165-1172
Abstract
Short-time low PEEP challenge (SLPC, application of additional 5 cmH2O PEEP to patients for 30 s) is a novel functional hemodynamic test presented in the literature. We hypothesized that SLPC could predict fluid responsiveness better than stroke volume variation (SVV) in mechanically ventilated intensive care patients. Heart rate, mean arterial pressure, stroke volume index (SVI) and SVV were recorded before SLPC, during SLPC and before and after 500 mL fluid loading. Patients whose SVI increased more than 15% after the fluid loading were defined as fluid responders. Reciever operating characteristics (ROC) curves were generated to evaluate the abilities of the methods to predict fluid responsiveness. Fifty-five patients completed the study. Twenty-five (46%) of them were responders. Decrease percentage in SVI during SLPC (SVIΔ%–SLPC) was 11.6 ± 5.2% and 4.3 ± 2.2% in responders and non-responders, respectively (p < 0.001). A good correlation was found between SVIΔ%–SLPC and percentage change in SVI after fluid loading (r = 0.728, P < 0.001). Areas under the ROC curves (ROC–AUC) of SVIΔ%–SLPC and SVV were 0.951 (95% CI 0.857–0.991) and 0.747 (95% CI 0.611–0.854), respectively. The ROC–AUC of SVIΔ%–SLPC was significantly higher than that of SVV (p = 0.0045). The best cut-off value of SVIΔ%–SLPC was 7.5% with 90% sensitivity and 96% specificity. The percentage change in SVI during SLPC predicts fluid responsiveness in intensive care patients who are ventilated with low tidal volumes; the sensitivity and specificity values are higher than those of SVV.Keywords
Funding Information
- Bilimsel Araştirma Projeleri Birimi, Istanbul Üniversitesi (33562)
This publication has 34 references indexed in Scilit:
- Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance*Critical Care Medicine, 2012
- Early Fluid Resuscitation Reduces Morbidity Among Patients With Acute PancreatitisClinical Gastroenterology and Hepatology, 2011
- Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*Critical Care Medicine, 2011
- The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension*Critical Care Medicine, 2010
- The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsivenessIntensive Care Medicine, 2009
- Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patientsCritical Care Medicine, 2009
- Review of A Large Clinical Series: Association of Cumulative Fluid Balance on Outcome in Acute Lung Injury: A Retrospective Review of the ARDSnet Tidal Volume Study CohortJournal of Intensive Care Medicine, 2008
- Does a positive end‐expiratory pressure‐induced reduction in stroke volume indicate preload responsiveness? An experimental studyActa Anaesthesiologica Scandinavica, 2007
- Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*Critical Care Medicine, 2007
- Changes in Arterial Pressure during Mechanical VentilationAnesthesiology, 2005