Monte Carlo-based inverse treatment planning
Authors:
- 22 July 1999
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 44 (8) , 1885-1896
Abstract
A Monte Carlo-based inverse treatment planning system (MCI) has been developed which combines arguably the most accurate dose calculation method (Monte Carlo particle transport) with a `guaranteed' optimization method (simulated annealing). A distribution of photons is specified in the tumour volume; they are transported using an adjoint calculation method to outside the patient surface to build up an intensity distribution. This intensity distribution is used as the initial input into an optimization algorithm. The dose distribution from each beam element from a number of fields is pre-calculated using Monte Carlo transport. Simulated annealing optimization is then used to find the weighting of each beam element, to yield the optimal dose distribution for the given criteria and constraints. MCI plans have been generated in various theoretical phantoms and patient geometries. These plans show conformation of the dose to the target volume and avoidance of critical structures. To verify the code, an experiment was performed on an anthropomorphic phantom.Keywords
This publication has 31 references indexed in Scilit:
- Forward and adjoint methods for radiotherapy planningMedical Physics, 1998
- Possibilities for tailoring dose distributions through the manipulation of electron beam characteristicsPhysics in Medicine & Biology, 1997
- Intensity modulated therapy and inhomogeneous dose to the tumor: A note of cautionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Physical vs. biological objectives for treatment plan optimizationRadiotherapy and Oncology, 1996
- Measured electron energy and angular distributions from clinical acceleratorsMedical Physics, 1996
- Decomposition of pencil beam kernels for fast dose calculations in three‐dimensional treatment planningMedical Physics, 1993
- Fitting of normal tissue tolerance data to an analytic functionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- A unified approach to the optimization of brachytherapy and external beam dosimetryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- Methods of image reconstruction from projections applied to conformation radiotherapyPhysics in Medicine & Biology, 1990
- Optimization of stationary and moving beam radiation therapy techniquesRadiotherapy and Oncology, 1988