Abstract
This letter proposes an active calibration method for millimeter-wave (mm-Wave) beamforming arrays that estimates the complex excitation of each element under realistic operating conditions. The method leverages a sequence of far-field transmission coefficient measurements collected while the array is rotated toward different angles. From these measurements, the complex excitation at each element is estimated without imposing any assumptions on the beamforming circuitry behavior. With all elements active during measurements, the estimated excitations inherently capture effects of mutual coupling and loading, which traditional elementwise calibration fails to account for. The method is validated on a $4{\,}\times {\,}4$ phased array operating at 38.5 GHz. Radiation patterns reconstructed from the estimated excitations match the measured patterns with a normalized root-mean-square error (NRMSE) better than −30 dB, confirming that the estimated excitations closely represent the true active-array behavior. In contrast, reconstructing the pattern using excitations obtained from elementwise measurements yields an NRMSE of only −8 dB. Furthermore, when beamforming toward boresight, the proposed active calibration method improves the measured boresight gain by 1.4 dB relative to passive calibration and reduces sidelobe-level imbalance by 2.4 dB. Finally, when the proposed method is applied for boresight null-steering, it achieves a null-depth that is 21.2 dB deeper than that obtained from passive calibration.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada

This publication has 10 references indexed in Scilit: