Determinants of fast marathon performance: low basal sympathetic drive, enhanced postcompetition vasodilatation and preserved cardiac performance after competition
Authors:
- 18 January 2008
- journal article
- Published by BMJ in British Journal of Sports Medicine
- Vol. 42 (11) , 882-888
Abstract
Objective: To test the hypothesis that enhanced postexercise vasodilatation is related to sympathetic drive to resistance vessels and to fast marathon performance. Design: Prospective field study before and after running a marathon. Participants: 51 healthy amateur runners who volunteered to participate. The fastest competitor finished fourth, the slowest 1290th out of 1324 participants. Interventions: None. Main outcome measurements: Competition time, beat-to-beat blood pressure by the vascular unloading technique, oscillometric blood pressure, beat-to-beat stroke volume by impedance cardiography, total peripheral resistance changes calculated from blood pressure and stroke volume changes, sympathetic modulation of vasomotor tone and parasympathetic modulation of sinus node function by spectral analysis of blood pressure and heart rate variability, baroreceptor reflex sensitivity by the sequence method. Results: Slow performers, in contrast to fast performers, exhibited a higher 0.1 Hz band of diastolic blood pressure variability before the competition (0.1 Hz BPV) (40.0 (SD 2.39) vs 54.9 (2.47), pConclusions: Fast performance in the marathon is associated with low sympathetic modulation of vasomotor tone, maintained stroke index postcompetition and enhanced exercise-induced vasodilatation. We postulate that maintaining a low level of sympathetic modulation to resistance vessels during the course of training may indicate its appropriateness, thus enabling fast performance by optimal postexercise vasodilatation and by prevention of postcompetition cardiac dysfunction. This will have to be tested in future longitudinal studies.Keywords
This publication has 20 references indexed in Scilit:
- Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurementComputers in Biology and Medicine, 2006
- Continuous non-invasive blood pressure monitoring using concentrically interlocking control loopsComputers in Biology and Medicine, 2006
- Impedance Cardiography as a Noninvasive Technique for Atrioventricular Interval Optimization in Cardiac Resynchronization TherapyJournal of Interventional Cardiac Electrophysiology, 2005
- Genes and human elite athletic performanceHuman Genetics, 2005
- Impact of marathon running on cardiac structure and function in recreational runnersClinical Science, 2004
- Syncope, falls and cobalamin deficiency in the old populationClinical Autonomic Research, 2004
- Autonomic dysfunction and hemodynamics in vitamin B12 deficiencyAutonomic Neuroscience, 2002
- A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic functionAn updated and improved software version for Windows 95/NT and the complete biosignal electronics (ECG, ICG, beat-to-beat and oscillometric blood pressure and pulse oxymetry) will be supplied in a compact instrument by: CNSystems Medical Equipment Inc. Heinrichstrasse 22 A-8010 Graz, Austria, Europe. Tel: +43/316/3631-0; Fax: +43/316/3631-20; E-mail: sales@cnsystems.at; Internet: http.//www.cnsytems.atComputers in Biology and Medicine, 1998
- Simultaneous measurement of stroke volume by impedance cardiography and nuclear ventriculography: Comparisons at rest and exerciseAnnals of Biomedical Engineering, 1989
- Acute blood biochemical alterations in response to marathon runningEuropean Journal of Applied Physiology, 1975