Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T
Authors:
- 7 June 2016
- journal article
- research article
- Published by Wiley in Journal of Neuroimaging
- Vol. 26 (5) , 503-510
Abstract
BACKGROUND AND PURPOSE: To compare an ultrafast brain magnetic resonance imaging (MRI) protocol to the conventional protocol in motion‐prone inpatient clinical settings.METHODS: This retrospective study was HIPAA compliant and approved by the Institutional Review Board with waived inform consent. Fifty‐nine inpatients (30 males, 29 females; mean age 55.1, range 23–93 years)who underwent 3‐Tesla brain MRI using ultrafast and conventional protocols, both including five sequences, were included in the study. The total scan time for five ultrafast sequences was 4 minutes 59 seconds. The ideal conventional acquisition time was 10 minutes 32 seconds but the actual acquisition took 15–20 minutes. The average scan times for ultrafast localizers, T1‐weighted, T2‐weighted, fluid‐attenuated inversion recovery (FLAIR), diffusion‐weighted, T2*‐weighted sequences were 14, 41, 62, 96, 80, 6 seconds, respectively. Two blinded neuroradiologists independently assessed three aspects: (1) image quality, (2) gray‐white matter (GM‐WM) differentiation, and (3) diagnostic concordance for the detection of six clinically relevant imaging findings. Wilcoxon signed‐rank test was used to compare image quality and GM‐WM scores. Interobserver reproducibility was calculated.RESULTS: The ultrafast T1‐weighted sequence demonstrated significantly better image quality (P = .005) and GM‐WM differentiation (P < .001) compared to the conventional sequence. There was high agreement (>85%) between both protocols for the detection of mass‐like lesion, hemorrhage, diffusion restriction, WM FLAIR hyperintensities, subarachnoid FLAIR hyperintensities, and hydrocephalus.CONCLUSIONS: The ultrafast protocol achieved at least comparable image quality and high diagnostic concordance compared to the conventional protocol. This fast protocol can be a viable option to replace the conventional protocol in motion‐prone inpatient clinical settings.Keywords
This publication has 26 references indexed in Scilit:
- Synthetic Mri of the Brain in a Clinical SettingActa Radiologica, 2012
- FLASH imaging: Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance, 2011
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Potential and feasibility of parallel MRI at high fieldNMR in Biomedicine, 2006
- Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokesJournal of Neurology, Neurosurgery & Psychiatry, 2005
- Highly parallel volumetric imaging with a 32‐element RF coil arrayMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a SecondScience, 1991
- High agreement but low Kappa: I. the problems of two paradoxesJournal of Clinical Epidemiology, 1990