Aim The air indoors has profound health implications as it can expose us to pathogens, allergens and particulates either directly or via contaminated surfaces. There is, therefore, an upsurge in marketing of air decontamination technologies, but with no proper validation of their claims. We addressed the gap through the construction and use of a versatile room-sized (25 m3) chamber to study airborne pathogen survival and inactivation. Methods and Results Here, we report on the quantitative recovery and detection of an enveloped (Phi6) and a non-enveloped bacteriophage (MS2). The two phages, respectively, acted as surrogates for airborne human pathogenic enveloped (e.g., influenza, Ebola and coronavirus SARS-CoV-2) and non-enveloped (e.g., norovirus) viruses from indoor air deposited directly on the lawns of their respective host bacteria using a programmable slit-to-agar air sampler. Using this technique, two different devices based on HEPA filtration and UV light were tested for their ability to decontaminate indoor air. This safe, relatively simple and inexpensive procedure augments the use of phages as surrogates for the study of airborne human and animal pathogenic viruses. Conclusions This simple, safe and relatively inexpensive method of direct recovery and quantitative detection of viable airborne phage particles can greatly enhance their applicattion as surrogates for the study of vertebrate virus survival in indoor air and assessment of technologies for their decontamination. Significance and Impact of the Study The safe, economical and simple technique reported here can be applied widely to investigate the role of indoor air for virus survival and transmission and also to assess the potential of air decontaminating technologies.Keywords
This publication has 14 references indexed in Scilit:
- Resistance of Aerosolized Bacterial Viruses to Four Germicidal ProductsPLOS ONE, 2016
- Airborne Infectious Agents and Other Pollutants in Automobiles for Domestic Use: Potential Health Impacts and Approaches to Risk MitigationJournal of Environmental and Public Health, 2016
- Decontamination of indoor air to reduce the risk of airborne infections: Studies on survival and inactivation of airborne pathogens using an aerobiology chamberAmerican Journal of Infection Control, 2016
- Assessing microbial decontamination of indoor air with particular focus on human pathogenic virusesAmerican Journal of Infection Control, 2016
- Disinfectant wipes are appropriate to control microbial bioburden from surfaces: use of a new ASTM standard test protocol to demonstrate efficacyJournal of Hospital Infection, 2015
- Bacteriophages in Food Fermentations: New Frontiers in a Continuous Arms RaceAnnual Review of Food Science and Technology, 2013
- Methods for Sampling of Airborne VirusesMicrobiology and Molecular Biology Reviews, 2008
- Application of a Quantitative Carrier Test to Evaluate Microbicides against MycobacteriaJournal of AOAC INTERNATIONAL, 2007
- Application of direct plaque assay for detection and enumeration of bacteriophages of Bacteroides fragilis from contaminated-water samplesApplied and Environmental Microbiology, 1990
- Spread of viral infections by aerosolsCritical Reviews in Environmental Control, 1987