Interlocking Telescopic Rod for Patients with Osteogenesis Imperfecta
- 1 May 2007
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 89 (5) , 1028-1035
Abstract
Background: Intramedullary fixation with use of a telescopic rod with a T-piece is one of the standard methods for long-bone stabilization in growing children with osteogenesis imperfecta. However, installation and removal of this device can cause substantial damage to the distal joint, which limits its use, especially in the tibia. We devised a modification of the telescopic rod system—the interlocking telescopic rod—in which the obturator is a simple rod with a hole, instead of a T-piece, at its distal end. Methods: The clinical and radiographic outcomes were evaluated more than two years following treatment of thirty-two limb segments (twenty-three tibiae and nine femora) with this new rod system in fifteen patients with osteogenesis imperfecta. Results: All rods were inserted without an arthrotomy of the distal joint, and all telescoped successfully. The interlocking pin used in the first five limb segments backed out between five and thirty-three months postoperatively. A revised fixation technique was used in the remaining twenty-seven limb segments, and the interlocking pin had not backed out at an average 3.1 years postoperatively. Proximal migration of the obturator was observed in four tibiae after 2.5 years. The cumulative survival rate of the rod at four years postoperatively was 88.7%. Conclusions: Both insertion and removal of an interlocking telescopic rod are much less invasive than insertion and removal of a conventional telescopic rod with a T-piece anchor. The interlocking pin at the distal epiphysis provides effective anchorage for telescoping. Our interim results showed survival of the device to be comparable with, or better than, that of the conventional telescopic rod. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.Keywords
This publication has 13 references indexed in Scilit:
- Sclerotic Metaphyseal Lines in a Child Treated With Pamidronate: Histomorphometric AnalysisJournal of Bone and Mineral Research, 2004
- Modern approach to children with osteogenesis imperfectaJournal of Pediatric Orthopaedics B, 2003
- Experience with Bailey-Dubow Rodding in Children with Osteogenesis ImperfectaEuropean Journal of Pediatric Surgery, 2000
- Complications of the Bailey-Dubow Elongating Nail in Osteogenesis ImperfectaJournal of Pediatric Orthopaedics B, 1999
- Complications after treatment of patients with osteogenesis imperfecta with a Bailey-Dubow rodArchives of orthopaedic and trauma surgery, 1998
- Functional Results of Operation in Osteogenesis ImperfectaJournal of Pediatric Orthopaedics, 1991
- Telescoping Intramedullary Stabilization of the Lower Extremities for Severe Osteogenesis ImperfectaJournal of Pediatric Orthopaedics, 1990
- Complications of Intramedullary Rods in Osteogenesis ImperfectaJournal of Pediatric Orthopaedics, 1988
- Genetic heterogeneity in osteogenesis imperfecta.Journal of Medical Genetics, 1979
- Fragmentation, Realignment, and Intramedullary Rod Fixation of Deformities of the Long Bones in ChildrenJournal of Bone and Joint Surgery, 1959