Validation of Garmin and Polar Devices for Continuous Heart Rate Monitoring During Common Training Movements in Tactical Populations
- 28 December 2022
- journal article
- research article
- Published by Taylor & Francis in Measurement in Physical Education and Exercise Science
- Vol. 27 (3) , 234-247
Abstract
Heart rate samples (n = 4500–8000) from wearables were compared to electrocardiography during a steady-state ruck (Ruck-S), maximal effort ruck (Ruck-M), submaximal cycle (Cycle), and Tabata Circuit. One device was worn at each location (wrist: Polar Grit-X, Garmin Fenix 6; chest-straps: Polar H10, Garmin HRM-Pro; armband: Polar Verity). Comparisons were made via percent error (MAPE) ≤5%, Concordance Correlation Coefficient (CCC), and ordinary least product regressions (OLP). H10 demonstrated strong agreement for all movements (MAPE = 1.28–3.40%, CCC = 0.93–0.99). During Ruck-S, Ruck-M, and Cycle, HRM-Pro (MAPE = 1.96–3.73%, CCC = 0.95–0.99) and Verity (MAPE = 1.84–5.36%, CCC = 0.98–0.99) demonstrated strong agreement. Fenix-6 demonstrated low MAPE (4.23–5.44%) and moderate to strong CCC (0.76–0.96) for Ruck-S, Ruck-M, and Cycle, while Grit-X had poor agreement (MAPE = 8.49–16.45%; CCC = 0.24–0.78). Tabata Circuit had the worst disagreement for all devices. Overall, chest straps and armbands demonstrated the strongest agreement, and should be worn when precise heart rate training is necessary.Keywords
Funding Information
- United States Army Combat Capabilities Development Command
This publication has 34 references indexed in Scilit:
- Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable DevicesJMIR mHealth and uHealth, 2017
- Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skinPhysiological Measurement, 2016
- Wearable Performance Devices in Sports MedicineSports Health: A Multidisciplinary Approach, 2015
- Validity of Consumer-Based Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2014
- Kubios HRV – Heart rate variability analysis softwareComputer Methods and Programs in Biomedicine, 2014
- Perceived exertion and heart rate models for estimating metabolic workload in elite British soldiers performing a backpack load-carriage taskApplied Physiology, Nutrition, and Metabolism, 2010
- Linear regression analysis for comparing two measurers or methods of measurement: But which regression?Clinical and Experimental Pharmacology and Physiology, 2010
- Estimation of Energy Expenditure in Healthy Adults From the YMCA Submaximal Cycle Ergometer TestEvaluation & the Health Professions, 2007
- A Concordance Correlation Coefficient to Evaluate Reproducibility1989
- The Validity and Practicality of Sun-Reactive Skin Types I Through VIArchives of Dermatology, 1988