Characterization of Geometric Uncertainties of a Dose Calibrator During Measurement of 90Y Activity
Open Access
- 12 May 2011
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 39 (2) , 125-130
Abstract
The performance and measurement of 90Y with a dose calibrator has always been a key point of several international recommendations, specifically in the case of the radiopharmaceutical 90Y-ibritumomab tiuxetan, among other applications, used in the treatment of non-Hodgkin lymphoma. The objective of the present work was to examine in detail some important sources of geometric errors that, if neglected, can lead to an increase in uncertainty about the measured activity of this β− emitter radionuclide. Methods: A CRC-15R dose calibrator was used to measure and quantify some of these sources, although the same methodology can easily be applied to any other similar equipment. The depth response along the main axis of the dose calibrator was carefully characterized, as well as syringe volume effects and source angular dependence. Results: It was found that, if not taken properly into account, these issues can contribute to an increase in the activity uncertainty (e.g., 5.1% in the present example). This finding implies the possibility of easily reaching higher values than the internationally suggested 5% uncertainty in activity measurement for therapeutic purposes. Conclusion: These errors can be greatly reduced by previous characterization of the dose calibrator and careful implementation of the methodology for measurement.Keywords
This publication has 7 references indexed in Scilit:
- Yttrium-90 TOF PET scan demonstrates high-resolution biodistribution after liver SIRTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- Syringe shape and positioning relative to efficiency volume inside dose calibrators and its role in nuclear medicine quality assurance programsApplied Radiation and Isotopes, 2009
- State of the Art in Nuclear Medicine Dose AssessmentSeminars in Nuclear Medicine, 2008
- A performance evaluation of 90Y dose-calibrator measurements in nuclear pharmacies and clinics in the United StatesApplied Radiation and Isotopes, 2008
- A new internal pair production branching ratio of 90Y: The development of a non-destructive assay for 90Y and 90SrApplied Radiation and Isotopes, 2007
- International guidance on the establishment of quality assurance programmes for radioactivity measurement in nuclear medicineApplied Radiation and Isotopes, 2006
- Experimental determination of calibration settings for plastic syringes containing solutions of 90Y using commercial radionuclide calibratorsApplied Radiation and Isotopes, 2004