Abstract
In this manuscript we describe the development and testing of a bipolar electrode for the simultaneous acquisition of ultrasound (US) images and surface electromyograms (EMGs) from the same muscle region. The developed electrode (bEMG-US) consists of two circular sensing regions (20 mm diameter) with fixed inter-electrode distance (3.5 cm, center-to-center). Both the sensing regions and the external structure of the electrode are made of hydrogel layers separated by insulating materials. The electrical properties (i.e., impedance and noise of the electrode-skin interface) and the quality of EMGs detected with the developed electrodes during electrically elicited contractions were assessed and compared with those provided by commercially available EMG electrodes. The effect of the bEMG-US electrode on US images was evaluated by comparing images detected from the same muscle region with and without the electrode interposed between the US probe and the skin. Tests on five subjects showed that the electrode-skin impedance of bEMG-US electrodes was higher than that of conventional EMG electrodes (mean (range): 15.6 (8.5-21.1) kΩ vs. 8.2 (4.9-16.5) kΩ). Despite higher impedance values, both electrode systems provided comparable, electrode-skin noise levels (1.4 (1.1-1.7) µV vs. 1.3 (1.0-1.5) µV) and M waves (normalized mean square error: 2.6 (0.6-6.8)%). The quality of US images detected with and without the bEMG-US electrode between the US probe and the skin was comparable, as demonstrated by the low errors in the estimation of anatomical variables in the two experimental conditions (range: (0.37-2.35) deg for pennation angle and (-0.31-0.1) cm for muscle thickness). Results demonstrate that bEMG-US can be used to acquire concurrently EMGs and US images from the same muscle region with a negligible effect on the quality of the two detected signals, thus allowing for a simultaneous, multimodal evaluation of muscle activation.Keywords
Funding Information
- Compagnia di San Paolo (Convenzione_CSP_2016_2018)
This publication has 23 references indexed in Scilit:
- How much does the human medial gastrocnemius muscle contribute to ankle torques outside the sagittal plane?Human Movement Science, 2013
- Impedance spectroscopy of conductive commercial hydrogels for electromyography and electroencephalographyPhysiological Measurement, 2010
- Effect of composition on the dielectric properties of hydrogels for biomedical applicationsPhysiological Measurement, 2010
- Dynamic imaging of skeletal muscle contraction in three orthogonal directionsJournal of Applied Physiology, 2010
- Heterogeneity of muscle activation in relation to force direction: A multi-channel surface electromyography study on the triceps surae muscleJournal of Electromyography and Kinesiology, 2009
- Discharge Properties of Motor Units of the Abductor Hallucis Muscle During Cramp ContractionsJournal of Neurophysiology, 2009
- Intra‐ and intermuscular variation in human quadriceps femoris architecture assessed in vivoJournal of Anatomy, 2006
- Calf muscle-tendon properties and postural balance in old ageJournal of Applied Physiology, 2006
- Task-oriented EMG activity recorded from partitions in human lateral gastrocnemius muscleJournal of Electromyography and Kinesiology, 1993
- Comprehensive compilation of empirical ultrasonic properties of mammalian tissuesThe Journal of the Acoustical Society of America, 1978