More is not always better: modeling the effects of elastic exoskeleton compliance on underlying ankle muscle–tendon dynamics
Authors:
- Dominic J FarrisDFDominic J Farris
- Gregory S SawickiGSGregory S Sawicki
- 24 November 2014
- journal article
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 9 (4) , 046018
Abstract
Development of robotic exoskeletons to assist/enhance human locomotor performance involves lengthy prototyping, testing, and analysis. This process is further convoluted by variability in limb/body morphology and preferred gait patterns between individuals. In an attempt to expedite this process, and establish a physiological basis for actuator prescription, we developed a simple, predictive model of human neuromechanical adaptation to a passive elastic exoskeleton applied at the ankle joint during a functional task. We modeled the human triceps surae-Achilles tendon muscle tendon unit (MTU) as a single Hill-type muscle, or contractile element (CE), and series tendon, or series elastic element (SEE). This modeled system was placed under gravitational load and underwent cyclic stimulation at a regular frequency (i.e. hopping) with and without exoskeleton (Exo) assistance. We explored the effect that both Exo stiffness (kExo) and muscle activation (Astim) had on combined MTU and Exo (MTU + Exo), MTU, and CE/SEE mechanics and energetics. Model accuracy was verified via qualitative and quantitative comparisons between modeled and prior experimental outcomes. We demonstrated that reduced Astim can be traded for increased kExo to maintain consistent MTU + Exo mechanics (i.e. average positive power (P⁺mech) output) from an unassisted condition (i.e. kExo = 0 kN · m⁻¹). For these regions of parameter space, our model predicted a reduction in MTU force, SEE energy cycling, and metabolic rate (Pmet), as well as constant CE P⁺mech output compared to unassisted conditions. This agreed with previous experimental observations, demonstrating our model's predictive ability. Model predictions also provided insight into mechanisms of metabolic cost minimization, and/or enhanced mechanical performance, and we concluded that both of these outcomes cannot be achieved simultaneously, and that one must come at the detriment of the other in a spring-assisted compliant MTU.Keywords
Funding Information
- US Israel Binational Science Foundation Start Up Grant (2011152)
This publication has 37 references indexed in Scilit:
- Autonomous exoskeleton reduces metabolic cost of human walking during load carriageJournal of NeuroEngineering and Rehabilitation, 2014
- A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human WalkingPLOS ONE, 2013
- Human medial gastrocnemius force–velocity behavior shifts with locomotion speed and gaitProceedings of the National Academy of Sciences, 2012
- Fifteen observations on the structure of energy-minimizing gaits in many simple biped modelsJournal of The Royal Society Interface, 2010
- Robotic lower limb exoskeletons using proportional myoelectric control2009
- The exoskeletons are hereJournal of NeuroEngineering and Rehabilitation, 2009
- Compliant leg behaviour explains basic dynamics of walking and runningProceedings Of The Royal Society B-Biological Sciences, 2006
- Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)IEEE/ASME Transactions on Mechatronics, 2006
- The force-driven harmonic oscillator as a model for human locomotionHuman Movement Science, 1990
- The spring-mass model for running and hoppingJournal of Biomechanics, 1989