Dosimetric Comparison of Intensity-Modulated Radiosurgery and Helical Tomotherapy for the Treatment of Multiple Intracranial Metastases
Open Access
- 1 October 2009
- journal article
- research article
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 8 (5) , 361-367
Abstract
The purpose of this study was to evaluate the dosimetry of single fraction, single-isocenter intensity-modulated radiosurgery (IMRS) plans for multiple intracranial metastases and to compare Helical Tomotherapy (HT). Ten treatment plans with 3–6 brain metastases treated with IMRS were re-planned with HT. The mean number of lesions was 5 and mean PTV 22 cm3. The prescribed dose was 16–20 Gy. The mean V100% was similar for IMRS and HT, and the mean conformity index was 1.4, mean Paddick confirmity index was 0.7, and mean MDPD was 1.1 for both. The mean gradient index was similar for both. The mean 50% isodose volume was 179.2 cm3 for IMRS and 277.0 cm3 for HT (p=0.01). The mean maximum doses to organs at risk were lower for IMRS except brainstem and right optic nerve. For brain, the integral dose was 5.1 and 6.8 Gy-kg (p<0.001) and mean dose 4.0 and 5.4 Gy (p<0.001) for IMRS and HT, respectively. The mean treatment times were 23 (IMRS) and 41 (HT) minutes. Conformity and homogeneity indices were equivalent and sparing of the organs at risk was clinically acceptable for both IMRS and HT. Though the gradient index was similar for IMRS and HT, the mean 50% isodose volume and integral dose to normal brain were lower for IMRS as was treatment time.Keywords
This publication has 22 references indexed in Scilit:
- Whole Brain Radiotherapy With Hippocampal Avoidance and Simultaneously Integrated Brain Metastases Boost: A Planning StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Simultaneous Infield Boost With Helical Tomotherapy for Patients With 1 to 3 Brain MetastasesAmerican Journal of Clinical Oncology, 2007
- Killing Two Birds with One Stone: A Dosimetric Study of Dual Target Radiosurgery Using a Single IsocenterTechnology in Cancer Research & Treatment, 2006
- A simple dose gradient measurement tool to complement the conformity indexJournal of Neurosurgery, 2006
- Stereotactic radiosurgery for four or more intracranial metastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Brain metastases: epidemiology and pathophysiologyJournal of Neuro-Oncology, 2005
- Nontumor integral dose variation in conventional radiotherapy treatment planningMedical Physics, 2003
- A simple scoring ratio to index the conformity of radiosurgical treatment plansJournal of Neurosurgery, 2000
- Iterative approaches to dose optimization in tomotherapyPhysics in Medicine & Biology, 1999
- An investigation of tomotherapy beam deliveryMedical Physics, 1997