Digital mammographic density and breast cancer risk: a case–control study of six alternative density assessment methods
Open Access
- 20 September 2014
- journal article
- research article
- Published by Springer Nature in Breast Cancer Research
- Vol. 16 (5) , 439
Abstract
Introduction: Mammographic density is a strong breast cancer risk factor and a major determinant of screening sensitivity. However, there is currently no validated estimation method for full-field digital mammography (FFDM). Methods: The performance of three area-based approaches (BI-RADS, the semi-automated Cumulus, and the fully-automated ImageJ-based approach) and three fully-automated volumetric methods (Volpara, Quantra and single energy x-ray absorptiometry (SXA)) were assessed in 3168 FFDM images from 414 cases and 685 controls. Linear regression models were used to assess associations between breast cancer risk factors and density among controls, and logistic regression models to assess density-breast cancer risk associations, adjusting for age, body mass index (BMI) and reproductive variables. Results: Quantra and the ImageJ-based approach failed to produce readings for 4% and 11% of the participants. All six density assessment methods showed that percent density (PD) was inversely associated with age, BMI, being parous and postmenopausal at mammography. PD was positively associated with breast cancer for all methods, but with the increase in risk per standard deviation increment in PD being highest for Volpara (1.83; 95% CI: 1.51 to 2.21) and Cumulus (1.58; 1.33 to 1.88) and lower for the ImageJ-based method (1.45; 1.21 to 1.74), Quantra (1.40; 1.19 to 1.66) and SXA (1.37; 1.16 to 1.63). Women in the top PD quintile (or BI-RADS 4) had 8.26 (4.28 to 15.96), 3.94 (2.26 to 6.86), 3.38 (2.00 to 5.72), 2.99 (1.76 to 5.09), 2.55 (1.46 to 4.43) and 2.96 (0.50 to 17.5) times the risk of those in the bottom one (or BI-RADS 1), respectively, for Volpara, Quantra, Cumulus, SXA, ImageJ-based method, and BI-RADS (P for trend P = 0.05), and Quantra slightly lower (AUC = 0.63; P = 0.06), than Cumulus (AUC = 0.65). Conclusions: Fully-automated methods are valid alternatives to the labour-intensive "gold standard" Cumulus for quantifying density in FFDM. The choice of a particular method will depend on the aims and setting but the same approach will be required for longitudinal density assessments.Keywords
This publication has 31 references indexed in Scilit:
- A first evaluation of breast radiological density assessment by QUANTRA software as compared to visual classificationThe Breast, 2012
- High-throughput mammographic-density measurement: a tool for risk prediction of breast cancerBreast Cancer Research, 2012
- Density is in the eye of the beholder: visual versus semi-automated assessment of breast density on standard mammogramsInsights into Imaging, 2011
- Localized Fibroglandular Tissue as a Predictor of Future Tumor Location within the BreastCancer Epidemiology, Biomarkers & Prevention, 2011
- Volume of Mammographic Density and Risk of Breast CancerCancer Epidemiology, Biomarkers & Prevention, 2011
- Volumetric Breast Density from Full-Field Digital Mammograms and Its Association with Breast Cancer Risk Factors: A Comparison with a Threshold MethodCancer Epidemiology, Biomarkers & Prevention, 2010
- Mammographic Density and Breast Cancer Risk: Evaluation of a Novel Method of Measuring Breast Tissue VolumesCancer Epidemiology, Biomarkers & Prevention, 2009
- Comparison of a New and Existing Method of Mammographic Density Measurement: Intramethod Reliability and Associations with Known Risk FactorsCancer Epidemiology, Biomarkers & Prevention, 2007
- Volumetric breast density estimation from full-field digital mammogramsIEEE Transactions on Medical Imaging, 2006
- Mammographic breast density as an intermediate phenotype for breast cancerThe Lancet Oncology, 2005