Abstract
The occurrence of damage on polished femoral stems has been widely reported in the literature, and bone cement has been implicated in a tribocorrosive failure process. However, the mechanisms of cement-mediated damage and the impact of cement formulation on this process are not well understood. In this study, 13 Zimmer CPT polished femoral stems, and the corresponding cement specimens were retrieved at revision surgery and analyzed using high-resolution imaging techniques. Surface damage attributed to tribocorrosion was observed on all stems. Corrosion product, in the form of black flaky surface debris, was observed on the surface of cement specimens; both energy-dispersive X-ray spectroscopy and inductively coupled plasma mass spectrometry(ICP-MS) confirmed the presence of cobalt and chromium, with the ICP-MS showing much higher levels of Cr compared to Co when compared to the original stem material. Agglomerates of ZrO2 radiopacifier were also identified on the cement surface and, in some cases, showed evidence of abrasive wear; the size of these particles correlated well with elliptical pitting evident on the surfaces of the corresponding stems. This evidence supports the hypothesis that agglomerates of hard radiopacifier particles within the cement may induce a wear-dominated tribocorrosive interaction at the stem–cement interface that damages the surface of polished CoCr femoral stems. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2027–2033, 2017.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/J001023/1)
This publication has 23 references indexed in Scilit:
- The contribution of the micropores in bone cement surface to generation of femoral stem wear in total hip replacementTribology International, 2011
- High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplastyInternational Orthopaedics, 2006
- Metallic Shedding, Surface Finish Changes, and Extensive Femoral Osteolysis in the Loose Spectron EF StemClinical Orthopaedics and Related Research, 2006
- Effect of synovial fluid, phosphate‐buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implantsJournal of Biomedical Materials Research Part A, 2005
- In Vivo surface wear mechanisms of femoral components of cemented total hip arthroplastiesThe Journal of Arthroplasty, 2004
- THA loading arising from increased femoral anteversion and offset may lead to critical cement stressesJournal of Orthopaedic Research, 2003
- The type of cement and failure of total hip replacementsThe Journal of Bone and Joint Surgery. British volume, 2002
- Cement migration after THRThe Journal of Bone and Joint Surgery. British volume, 1999
- Crevice Corrosion of Cemented Titanium Alloy Stems in Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996
- The effects of proteins on metallic corrosionJournal of Biomedical Materials Research, 1982