Reference equations for pulmonary diffusing capacity using segmented regression show similar predictive accuracy as GAMLSS models
Open Access
- 16 February 2022
- journal article
- research article
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 9 (1) , e001087
Abstract
Purpose: To determine whether generalised additive models of location, scale and shape (GAMLSS) developed for pulmonary diffusing capacity are superior to segmented (piecewise) regression models, and to update reference equations for pulmonary diffusing capacity for carbon monoxide (DLCO) and nitric oxide (DLNO), which may be affected by the equipment used for its measurement. Methods: Data were pooled from five studies that developed reference equations for DLCO and DLNO (n=530 F/546 M; 5–95 years old, body mass index 12.4–39.0 kg/m2). Reference equations were created for DLCO and DLNO using both GAMLSS and segmented linear regression. Cross-validation was applied to compare the prediction accuracy of the two models as follows: 80% of the pooled data were used to create the equations, and the remaining 20% was used to examine the fit. This was repeated 100 times. Then, the root-mean-square error was compared between both models. Results: In males, GAMLSS models were 7% worse to 3% better compared to segmented regression for DLCO and DLNO. In females, GAMLSS models were 2% worse to 5% better compared to segmented linear regression for DLCO and DLNO. The Hyp'Air Compact measured DLNO and alveolar volume (VA) that was approximately 16–20 mL/min/mm Hg and 0.2–0.4 L higher, respectively, compared to the Jaeger MasterScreen Pro. The measured DLCO was similar between devices after controlling for altitude. Conclusions: For the development of pulmonary function reference equations, we propose that segmented linear regression can be used instead of GAMLSS due to its simplicity, especially when the predictive accuracy is similar between the two models, overall.Keywords
This publication has 78 references indexed in Scilit:
- Significant blood resistance to nitric oxide transfer in the lungJournal of Applied Physiology, 2010
- Reference Ranges for Spirometry Across All AgesAmerican Journal of Respiratory and Critical Care Medicine, 2008
- A Comparison of Parametric and Nonparametric Methods for Normalising cDNA Microarray DataBiometrical Journal, 2007
- Estimating regression models with unknown break‐pointsStatistics in Medicine, 2003
- Worm plot: a simple diagnostic device for modelling growth reference curvesStatistics in Medicine, 2001
- Smoothing reference centile curves: The lms method and penalized likelihoodStatistics in Medicine, 1992
- Methodology for generating continuous prediction equations for pulmonary function measuresComputers and Biomedical Research, 1991
- A New Biometrical Procedure for Testing the Equality of Measurements from Two Different Analytical Methods. Application of linear regression procedures for method comparison studies in Clinical Chemistry, Part IClinical Chemistry and Laboratory Medicine (CCLM), 1983
- Estimating the Dimension of a ModelThe Annals of Statistics, 1978
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974