Cell response to AcrySof intraocular lenses in an Indian population
- 1 July 2002
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 28 (7) , 1173-1181
Abstract
To evaluate the quantitative cytological response to AcrySof (Alcon) intraocular lenses (IOLs) in an Indian population by studying the incidence, fate, progression, and severity of cell deposits after uneventful phacoemulsification. Iladevi Cataract & IOL Research Center, Ahmedabad, India. This clinical prospective study comprised 64 eyes of 64 healthy patients with senile cataract and no other ocular pathology having phacoemulsification and implantation of an AcrySof IOL. The eyes were observed for cell deposits. One week and 1, 3, 6, 12, and 15 months postoperatively, specular reflex was obtained by slitlamp biomicroscopy under x 20 magnification to record the incidence, progression, morbidity, and severity of small and large (including giant) cells on the IOLs. The highest incidence of small cells was 18.7%. The cell deposits appeared at 1 week, peaked at 1 month, and were gone after 6 months. The severity was never more than grade 2 (5 to 10 cells). The highest incidence of large cells, including giant cells, was 23.4%. The deposits appeared at 1 month, peaked at 3 months, and were gone after 12 months. The severity was never more than grade 2 (3 to 5 cells). The highest incidence of giant cells was 6.2%. The deposits appeared at 3 months and were gone by 15 months. Severity was never more than grade 1 (2 cells). No IOL had cell deposits at the last follow-up (mean 14 months +/- 3.25 [SD]). The incidence, and especially the severity, of cell deposits in the Indian population was low. All cell types, including giant cells, disappeared within 12 months. This could reflect the biocompatibility of the AcrySof IOL and the appropriate surgical technique.Keywords
This publication has 22 references indexed in Scilit:
- Cellular reaction on the anterior surface of 4 types of intraocular lensesJournal of Cataract & Refractive Surgery, 2001
- Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surfaceJournal of Cataract & Refractive Surgery, 1998
- Postoperative inflammatory response to phacoemulsification and extracapsular cataract surgery: Aqueous flare and cellsJournal of Cataract & Refractive Surgery, 1996
- Cellular reaction on the anterior surface of poly(methyl methacrylate) intraocularlensesJournal of Cataract & Refractive Surgery, 1996
- In vivo documentation of cellular reactions on lens surfaces for assessing the biocompatibility of different intraocular implantsEye, 1994
- Comparative Study of Intraocular Lens Implantation Through 3.2- and 5.5-mm IncisionsOphthalmology, 1994
- In vivo Observation of Surface Precipitates of 200 Consecutive Hydrogel Intraocular LensesOphthalmologica, 1992
- Cellular invasion on hydrogel and poly(methyl methacrylate) implantsJournal of Cataract & Refractive Surgery, 1991
- Comparison of Heparin Surface Modified and Ordinary PCLs: A Japanese StudyEuropean journal of Implant and Refractive Surgery, 1991
- Effect of Intraocular Lens Fixation on the Blood-Aqueous BarrierAmerican Journal of Ophthalmology, 1984