Methodology investigation of expirograms for enabling contact free breath alcohol analysis
Authors:
- B HökBHB Hök
- L AnderssonLAL Andersson
- G HedenstiernaGHG Hedenstierna
- 17 June 2009
- journal article
- Published by IOP Publishing in Journal of Breath Research
- Vol. 3 (3) , 036002
Abstract
The present techniques for breath alcohol determination have usability limitations concerning practical use and the time and effort required for the test person. The rationale of the physiological assumptions in a recently demonstrated technique for breath analysis without a mouthpiece is investigated in this paper. Expirograms quantifying ethanol, carbon dioxide (CO(2)) and water (H(2)O) from 30 test subjects were analysed, with respect to the influence of individual variations in end-expiratory CO(2) and H(2)O concentrations, and possible benefits from simultaneous measurement of CO(2) or H(2)O. Both healthy subjects and patients suffering from pulmonary diseases performed breath tests with small and maximum volume expiration. The breath tests were recorded basically with a standard evidential instrument using infrared absorption spectroscopy, and equipped with a mouthpiece. Average concentrations were significantly higher for the maximum than for the small expirations. For the maximum expirations, the healthy subjects had a significantly higher end-expired PCO(2) of 4.4 ± 0.5 kPa (mean ± standard deviation) than the patients (3.9 ± 0.7 kPa). The corresponding values for H(2)O were 39 ± 1 and 38 ± 1 mg l(-1). The results indicate that the CO(2) variability is consistent with the requirements of accuracy for alcohol ignition interlocks. In addition, CO(2) as tracer gas is preferable to H(2)O due to its low concentration in ambient air. In instruments for evidential purposes H(2)O may be required as tracer gas for increased accuracy. Furthermore, the study provides support for early determination of breath alcohol concentration, indicating that determination after 2 s will introduce an additional random error of 0.02 mg l(-1) or less.Keywords
This publication has 12 references indexed in Scilit:
- Breath alcohol concentration determined with a new analyzer using free exhalation predicts almost precisely the arterial blood alcohol concentrationForensic Science International, 2007
- Breath tests and airway gas exchangePulmonary Pharmacology & Therapeutics, 2007
- The alcohol breath test—a reviewJournal of Applied Physiology, 1998
- Resting End-Tidal CO2 Association with Age, Gender, and PersonalityPsychosomatic Medicine, 1998
- Comparison of the End-Tidal Arterial Pco2 Gradient During Exercise in Normal Subjects and in Patients With Severe COPDChest, 1995
- Capnometry for continuous postoperative monitoring of nonintubated, spontaneously breathing patientsJournal of Clinical Monitoring and Computing, 1991
- Reference Values for Lung Function Tests in Men: Regression Equations with Smoking VariablesUpsala Journal of Medical Sciences, 1986
- The Arterial to End-Expiratory Carbon Dioxide Tension Gradient in Acute Pulmonary Embolism and Other Cardiopulmonary DiseasesChest, 1974
- Arterial oxygen tension in acute myocardial infarction. Serial analysis of clinical state and blood gas changesAmerican Heart Journal, 1970
- Studies on Myocardial Infarction in Malmö 1935 to 19541Acta Medica Scandinavica, 1959