Design of an active-differentiator-based capacitance transducer for electrical capacitance tomography
Authors:
- 1 August 1997
- journal article
- design note
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 8 (8) , 947-950
Abstract
This paper focuses on the development of new sensor electronics for electrical capacitance tomography to increase the measurement accuracy and, accordingly, to enhance the system performance in terms of image resolution, and the data acquisition speed. The new system relies on the use of the unknown capacitance in an active differentiator. Applying an appropriate input signal to the differentiator gives an output which can easily be translated into the capacitance.Keywords
This publication has 2 references indexed in Scilit:
- Analysis of chaos in fluidization using electrical capacitance tomographyMeasurement Science and Technology, 1996
- Design of sensor electronics for electrical capacitance tomographyIEE Proceedings G Circuits, Devices and Systems, 1992