Laboratory Cross-Sensitivity Evaluation of Low-Cost Electrochemical Formaldehyde Sensors
Open Access
Abstract
Formaldehyde is the most abundant carbonyl globally and the biggest driver of cancer risk in the United States among hazardous air pollutants. Ambient formaldehyde concentration measurements are generally sparse due to high measurement costs and limited measurement infrastructure. Recent studies have used low-cost air quality sensors to affordably improve spatial coverage and provide real-time measurements. Our previous research evaluated the laboratory performance of a low-cost electrochemical formaldehyde sensor (Sensirion SFA30) over formaldehyde concentrations ranging from 0 to 76 ppb. The sensors exhibited good linearity of response, a low limit of detection, and good accuracy in detecting formaldehyde. This study evaluated the cross-sensitivity of the SFA30 and the Gravity sensors (electrochemical formaldehyde sensors) over formaldehyde concentrations ranging from 0 to 326 ppb in a laboratory evaluation system, with broadband cavity-enhanced absorption spectroscopy used to obtain the reference measurements. We evaluated the sensors in a mixture of formaldehyde with five outdoor trace gases (CO, NO, NO2, O3, and isobutylene) and two indoor VOCs (methanol and isopropyl alcohol). The results suggest that the Gravity sensors may be useful for outdoor formaldehyde measurements when formaldehyde levels are well above background levels and that the SFA30 sensors may be useful screening tools for indoor environments, if properly calibrated.Keywords
Funding Information
- National Science Foundation (10054273)
This publication has 53 references indexed in Scilit:
- Evaluation of low-cost formaldehyde sensors calibrationBuilding and Environment, 2022
- Ultrasensitive detection of formaldehyde at room temperature using Si-chip assisted MOS/SiNWs nanocomposite based sensorJournal of Alloys and Compounds, 2022
- Visible light-assisted formaldehyde sensor based on HoFeO3 nanoparticles with sub-ppm detection limitCeramics International, 2020
- Low-cost sensors as an alternative for long-term air quality monitoringEnvironmental Research, 2020
- A high sensitive and low detection limit of formaldehyde gas sensor based on hierarchical flower-like CuO nanostructure fabricated by sol–gel methodJournal of Materials Science: Materials in Electronics, 2016
- Comparison of the toxicity of diesel exhaust produced by bio- and fossil diesel combustion in human lung cells in vitroAtmospheric Environment, 2013
- The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networksAtmospheric Environment, 2013
- Cancer effects of formaldehyde: a proposal for an indoor air guideline valueArchives of Toxicology, 2010
- Chemistry of secondary organic aerosol: Formation and evolution of low-volatility organics in the atmosphereAtmospheric Environment, 2008
- Formaldehyde and cancer: a critical reviewInternational Archives of Occupational and Environmental Health, 1994