Comparison of Two Positions of Knee Arthrocentesis
Authors:
- Ting ZhangTZTing Zhang
- Honghua LvHLHonghua Lv
- Lidan XieLXLidan Xie
- Weidong WuWWWeidong Wu
- Jianping WuJWJianping Wu
- Xuelian WuXWXuelian Wu
- 1 July 2012
- journal article
- research article
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 91 (7) , 611-615
Abstract
Many studies have focused on the accuracy rate of intraarticular injection. However, sometimes, even when the needle enters the joint cavity accurately, it can be difficult to obtain a sufficient amount of joint fluid. This problem may be attributable to the position of the knee during arthrocentesis. The purpose of this prospective study was to determine which position, supine or sitting, would yield more joint fluid during knee arthrocentesis. In this study, 40 knees belonging to 30 patients with osteoarthritis were examined. The patients were randomized between the supine position group (20 knees) and the sitting position group (20 knees). A "blind" aspiration was performed on each group. The volume of aspirated joint fluid (in milliliters) (V(1)) was recorded for each knee. Each knee was then checked by ultrasound immediately after aspiration. If there was more than a depth of 2 mm of knee effusion, then a second knee arthrocentesis was performed using ultrasound guidance. The aspirated joint fluid volume (in milliliters) (V(2)) was recorded for each knee. The value V(1)/V(1) + V(2) was calculated for each knee. The data were analyzed using the SPSS 16.0 statistical package program. In the supine position group, the "dry tap" rate was 10% in the first arthrocentesis, and 30% of the knees needed a second arthrocentesis. In the sitting position group, the dry tap rate was 25% in the first arthrocentesis, and 75% of the knees needed a second arthrocentesis. There was a significant difference in the V(1)/V(1) + V(2) values between the two groups (P = 0.02). In our study, more joint fluid was aspirated from patients in the supine position than from patients in the sitting position.Keywords
This publication has 7 references indexed in Scilit:
- A comparison of intra-articular hyaluronan injection accuracy rates between three approaches based on radiographic severity of knee osteoarthritisOsteoarthritis and Cartilage, 2008
- Primer: pitfalls of aspiration and injectionNature Clinical Practice Rheumatology, 2007
- ACCURACY OF NEEDLE PLACEMENT INTO THE INTRA-ARTICULAR SPACE OF THE KNEEJournal of Bone and Joint Surgery, 2002
- Importance of synovial fluid aspiration when injecting intra-articular corticosteroidsAnnals of the Rheumatic Diseases, 2000
- Knee Aspiration and InjectionThe Physician and Sportsmedicine, 1998
- Das Synovia-Volumen gesunder und arthrotischer menschlicher Kniegelenke*Zeitschrift für Orthopädie und ihre Grenzgebiete, 1996
- CAPSULAR COMPLIANCE AND PRESSURE-VOLUME RELATIONSHIPS IN NORMAL AND ARTHRITIC KNEESThe Journal of Bone and Joint Surgery. British volume, 1972