IMU-based Assessment of Ankle Inversion Kinematics and Orthosis Migration
Authors:
- 1 July 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 6395-6400
Abstract
Ankle orthoses are used to prevent injuries during very fast inversion motions of the ankle. In order to provide proper protection, they must fit well and migrate as little as possible. Inertial measurement units (IMUs) have become a useful tool for accurate motion analysis and are frequently used for gait analysis. In the present paper, we examine orthosis migration and inversion kinematics of human ankles protected and unprotected by an orthosis. We present two test benches that were developed for these purposes, as well as a set of inertial sensor fusion methods that are used to determine kinematic parameters from the sensor readings. To avoid the common but restrictive assumption of a homogeneous magnetic field, we determine all motion parameters without the use of magnetometer readings. We conduct a measurement series to compare the proposed IMU-based method to alternative camera-based and goniometer-based methods. Using two different ankle orthosis prototypes, we demonstrate that the proposed IMU-based methods facilitate accurate assessment of orthosis migration and ankle inversion kinematics.Keywords
This publication has 17 references indexed in Scilit:
- Review of ankle inversion sprain simulators in the biomechanics laboratoryAsia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 2015
- Realtime assessment of foot orientation by Accelerometers and GyroscopesCurrent Directions in Biomedical Engineering, 2015
- Healthcare algorithms by wearable inertial sensors: a surveyChina Communications, 2015
- Inertial Sensor-Based Smoother for Gait AnalysisSensors, 2014
- Biomechanical Comparison of 3 Ankle Braces With and Without Free Rotation in the Sagittal PlaneJournal of Athletic Training, 2014
- Cold water immersion of the ankle decreases neuromuscular response of lower limb after inversion movementBrazilian Journal of Physical Therapy, 2014
- Unloading reaction during sudden ankle inversion in healthy adultsGait & Posture, 2014
- Kinematics and kinetics of an accidental lateral ankle sprainJournal of Biomechanics, 2011
- Identification of ankle sprain motion from common sporting activities by dorsal foot kinematics dataJournal of Biomechanics, 2010
- Magnetic distortion in motion labs, implications for validating inertial magnetic sensorsGait & Posture, 2009