Impact of CT attenuation correction by SPECT/CT in brain perfusion images
Authors:
- 26 January 2012
- journal article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 26 (3) , 241-247
Abstract
The aim of this study was to elucidate the regional differences between brain perfusion single photon emission computed tomography (SPECT) images reconstructed with a uniform attenuation correction using Chang’s method (AC-Chang) and a non-uniform attenuation correction with CT using SPECT/CT (AC-CT). SPECT images of a phantom with and without head holder were obtained, and reconstructed images of AC-Chang and AC-CT were compared. Twenty-eight consecutive patients with brain disease examined by SPECT/CT brain perfusion imaging were selected, and images were reconstructed with AC-Chang and AC-CT. The AC-Chang and AC-CT reconstructed images were then compared by voxel-based analysis using three-dimensional stereotactic surface projections. Counts in the frontal area of the AC-Chang phantom image with head holder were higher than those in the posterior area. Counts in the frontal area of the AC-Chang clinical images were significantly higher than those in the AC-CT images, while the counts in the margin of the frontal lobe and posterior margin of the parietal, occipital cortices and cerebellum of the AC-Chang images were significantly lower. Relative frontal perfusion was 5.0% higher and relative cerebellar perfusion was 4.6% lower in the AC-Chang images relative to the AC-CT images, on average. We demonstrated the frontal dominant hyper-perfusion and parieto-occipital and cerebellar hypo-perfusion in brain SPECT images reconstructed with AC-Chang compared to those reconstructed with AC-CT. We suggest that to obtain an accurate attenuation-corrected brain perfusion SPECT image, attenuation correction by Chang’s method is inadequate.Keywords
This publication has 8 references indexed in Scilit:
- Comparison of advanced iterative reconstruction methods for SPECT/CTZeitschrift für Medizinische Physik, 2012
- CT Nonuniform Attenuation and TEW Scatter Corrections in Brain Tc-99m ECD SPECTClinical Nuclear Medicine, 2011
- The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect QuantificationInternational Journal of Molecular Imaging, 2011
- Quantitative Accuracy of Clinical 99mTc SPECT/CT Using Ordered-Subset Expectation Maximization with 3-Dimensional Resolution Recovery, Attenuation, and Scatter CorrectionJournal of Nuclear Medicine, 2010
- A review on the clinical uses of SPECT/CTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- SPECTCT cerebral perfusion scintigraphy; is the low-dose CT component of diagnostic value?Clinical Radiology, 2008
- A method for attenuation and scatter correction of brain SPECT based on computed tomography imagesNuclear Medicine Communications, 2003
- Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2000