Increased Bloodstream Infection Rates in Surgical Patients Associated with Variation from Recommended Use and Care Following Implementation of a Needleless Device
Authors:
- 2 January 1998
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 19 (1) , 23-27
Abstract
Objective: To determine if an apparent increase in bloodstream infections (BSIs) in patients with central venous catheters (CVCs) was associated with the implementation of a needleless access device. Design: Retrospective cohort study using a derived CVC-days factor for estimating appropriate denominator data. Setting: A 350-bed urban, acute, tertiary-care hospital. Methods: BSI surveillance data were obtained, and high-risk areas for BSIs were determined. A random 5% sample of medical records was used to estimate CVC days, and a cohort study was conducted to compare BSI rates before and during needleless device use. A survey was conducted of nursing needleless-device practices. Results: The surgical intensive-care unit (SICU), the medical intensive-care unit, and the solid organ transplant unit (OTU) were identified as high-risk units. Using existing surveillance BSI data and the estimated CVC days, the catheter-related BSI rates in the high-risk surgical patients were significantly higher during the needleless-device period compared with the preneedleless-device period (SICU, 9.4 vs 5.0/1,000 CVC days; OTU, 13.6 vs 2.2/1,000 CVC days). A survey of the nurses revealed that 60% to 70% were maintaining the needleless devices correctly. Conclusion: We observed a significant increase in the BSI rate in two surgical units, SICU and OTU, associated with introduction of a needleless device. This increase occurred shortly after the needleless device was implemented and was associated with nurses' unfamiliarity with the device, and needless-device use and care practices different from the manufacturer's recommendations.Keywords
This publication has 4 references indexed in Scilit:
- Use of an Estimation Method to Derive an Appropriate Denominator to Calculate Central Venous Catheter-Associated Bloodstream Infection RatesInfection Control & Hospital Epidemiology, 1998
- Evaluation of the acceptability of a needleless vascular-access system by nursesAmerican Journal of Infection Control, 1997
- Bloodstream infections in home infusion patients: The influence of race and needleless intravascular access devicesThe Journal of Pediatrics, 1996
- Bloodstream Infections Associated With a Needleless Intravenous Infusion System in Patients Receiving Home Infusion TherapyJAMA, 1995